RecordWell Data

Southport Marina

21 56TH ST, Kenosha, WI 53140 · Kenosha County

13cited violations
3serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Kenosha County Division of Health
License / ID
NFRY-8XQ4GM
Status
Permitted
Phone
(262) 657-5565
Official record
Kenosha County Division of Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20243133
2023100

Inspections

  1. Sep 11, 2024 Re-inspection 2 · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter plunger is not being maintained in operating condition. Flowmeter bobber is not moving within meter. Instructed Pool Manager to replace flow meter. Manager has submitted to KCPH a copy of work estimate from Platinum Pool Construction Care who recommends cutting and removing sections of piping and lenghtening flowmeter run per manufacturer instructions. Work is estimated to be completed by September 13, 2024.

      Correction: Adjust or repair the flowmeter plunger.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

  2. Aug 27, 2024 Re-inspection · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter plunger is not being maintained in operating condition. Flowmeter bobber is not moving within meter. Instructed Pool Manager to replace flow meter. Manager has submitted to KCPH a copy of work estimate from Platinum Pool Construction Care who recommends cutting and removing sections of piping and lenghtening flowmeter run per manufacturer instructions. Work is estimated to be completed by September 13, 2024.

      Correction: Adjust or repair the flowmeter plunger.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

  3. Aug 2, 2024 Routine · 3 critical, 7 non-critical
    • Not serious Non-critical

      INLETS CHECKED AND ADJUSTED

      Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Inlets are pointed in all directions. Discussed with staff on having all inlets adjusted to ensure uniform distribution.

      Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.

      Code ATCP 76.11(2)(c) - INLETS POSITIONED

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter plunger is not being maintained in operating condition. Flowmeter plunger is stuck and discussed with staff on getting unstuck.

      Correction: Adjust or repair the flowmeter plunger.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      SAFETY DATA SHEET

      A safety data sheet was not available for chemicals. Discussed with staff on getting safety data sheet for all chemicals.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      TEST KIT APPROVED

      Facility is not using approved test kits. Discussed with staff on using an approved test kit.

      Correction: Facility needs to be using an approved test kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Whirlpool was not tested today and no daily log is being recorded for testing daily. Discussed with staff on testing water quality standards daily and recording it.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area. Pool has one emergecny blanket. Discussed with staff on getting another emergency blanket.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool equipment is not properly maintained. Whirlpool controller is not being maintained and is not able to measure the pH and ORP correctly. Discussed with staff repairing or replacing whirlpool controller

      Correction: Maintain the pool equipment whirlpool controller.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool equipment is not properly maintained. Inlet covers and eyeballs are missing or broken. Discussed with staff on repairing inlet covers and eyeballs

      Correction: Maintain the pool equipment Inlets covers and eyeballs.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.8 for chlorine. Whirlpool is temporly closed. Discussed with staff on increasing levels of chlorine until it needs minium requirements of 3ppm. Staff was able to bring chlorine to 3ppm

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Corrected on site

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Discussed with staff on repairing or replacing emergency response phone. Staff was able to get a new phone in that works.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical Corrected on site

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. Whirlpool equalizer cover is coming off and grates are missing screws. Discussed with staff in repairing or replacing grates. Staff was able to add screws and cover is secured.

      Correction: Correct the hazardous condition of the whirlpool equalizer cover.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

  4. Jun 21, 2023 Routine · No items found

    No violations cited.

Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.