Village Of Pleasant Pr: Rec Plex
9900 TERWALL TER, Pleasant Prairie, WI 53158 · Kenosha County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Kenosha County Division of Health
- License / ID
- NFRY-8XQ4HX
- Status
- Permitted
- Phone
- (262) 947-0437
- Official record
- Kenosha County Division of Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2024 | 3 | 25 | 3 |
Inspections
-
Nov 12, 2024 Routine · 1 critical, 7 non-critical, 3 repeat
-
Not serious
Non-critical
CURRENT LICENSE
A pool, opened to the public, is located on the premises does not have a current license. Expired license is posted on window. Instructed Director to post current license. Director will post current license in an area visible to the public.
Correction: The pool must be closed to the public immediately and may not operate until a valid license is issued from the department.
Code ATCP 76.05(1)(a) - LICENSE CURRENT
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Observed chipping on multiple gutter anchors, resulting in rough, sharp areas that are not easily cleanable. Instructed Coordinator to repair chipping on gutter anchors to create a smooth, cleanable surface. Coordinator stated gutter anchors will be repaired.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
Corrected on site
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Observed alkalinity test has not been performed in more than a week. Instructed Manager to test for alkalinity once per week. Manager will test alkalinity once per week.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN-SQUARE FOOTAGE
Lifeguard Staffing Plan need to indicate square footage of pool basin. Lifeguard staffing plan does not indicate square footage of pool. Instructed Maintenance Manager to provide documentation of pool basin square footage. Manager will submit documentation of required square footage.
Correction: Provide documentation of pool basin square footage.
Code ATCP 76.22(1)(b)1. - SQUARE FOOTAGE
-
Not serious
Non-critical
Repeat
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone. Emergency telephone is located in Aquatics Coordinator's office, which remains unlocked to allow access by public. Instructed Coordiator to post signage stating the location of the telephone, emergency numbers, and facility address. Coordinator will post a sign near the phone instructing the public to the location of the phone, emergency numbers, and facility address.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Observed chipped and craked tiles on pool deck. Instructed Coodinator to replace chipped tiles. Coordinator stated a tile replacement where needed has been ordered.
Correction: Maintain pool deck area in good repair; deck tiles free of cracks and chipping.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Observed deck grates missing anchoring bolts. Instructed Coodinator to replace bolts. Coordinator stated deck grates replacement where needed has been ordered and will be completed in August, 2025.
Correction: Maintain pool deck area in good repair; deck tiles free of cracks and chipping.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Observed pump leaking. Instructed Manager to ensure pump does not leak. Manager will maintain pump free of leaks.
Correction: Maintain the pool equipment [Describe].
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
Corrected on site
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close. Both Emergency exit doors do not self close. Instructed Maintenance Manager to ensure both doors are self-closing. Manager will repair doors to ensure the self-closing mechanism is operational.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
-
May 16, 2024 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
FILTER MEDIA INSPECTED ANNUALLY
Filter media is not being inspected annually or cleaned or replaced as necessary.Staff informed me that filter media has not been inspectied last year. Discussed with staff filter media needs to be inspected annually..
Correction: Inspect the filters annually and clean and replace media as needed.
Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Some of the panels on gutter system, the paint is chipping off. Disucssed with staff on repairing of replacing chipping panels.
Correction: Maintain the pool equipment panels on gutter system. Corrected by 5/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Pump is leaking small amounts of water. Discussed with staff on repairing or replacing the leak on the pump. Staff informed me that they may be getting a new pump.
Correction: Maintain the pool equipment pump.Corrected by 7/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Some of the hand railings are loose. Discussed with staff on tighten the hand railings.
Correction: Maintain the pool equipment hand railings. Corrected by 5/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Pipe in pool area insulation is coming off. Disucssed with staff on fixing it.
Correction: Maintain the pool equipment pipe. Corrected by 7/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
-
Apr 8, 2024 Routine · 2 critical, 6 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The influcent gauge is not being maintained in operating condition. Influcent gauge is falling off from wall. Disucssed with staff on remounting influncent gauge.
Correction: Adjust or repair the influcent gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
FILTER MEDIA INSPECTED ANNUALLY
Filter media is not being inspected annually or cleaned or replaced as necessary.Staff informed me that filter media has not been inspectied last year. Discussed with staff filter media needs to be inspected annually..
Correction: Inspect the filters annually and clean and replace media as needed.
Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Combined chlorine is not being test. Discussed with staff that combined chlorine needs to be tested twice.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Alkalinity is not being test. Discussed with staff that alkalinity needs to be tested once a week
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone. None of the phones in the pool area have signs with emegency contacts listed. Discussed with staff on getting a sign for each phone in
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Pipe in pool area insulation is coming off. Disucssed with staff on fixing it.
Correction: Maintain the pool equipment pipe. Corrected by 7/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Some of the hand railings are loose. Discussed with staff on tighten the hand railings.
Correction: Maintain the pool equipment hand railings. Corrected by 5/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Pump is leaking small amounts of water. Discussed with staff on repairing or replacing the leak on the pump. Staff informed me that they may be getting a new pump.
Correction: Maintain the pool equipment pump.Corrected by 7/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Some of the panels on gutter system, the paint is chipping off. Disucssed with staff on repairing of replacing chipping panels.
Correction: Maintain the pool equipment panels on gutter system. Corrected by 5/8/2024
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
Corrected on site
LIFEGUARD AND ATTENDANT STAFFING REQUIREMENTS, TABLES A AND B
The pool is not adequately staffed.Pool was opened with no lifeguard present while a swimmer was in a pool over 2,000sqft. and sign was placed saying swim at your own risk. Discussed with staff that lifeguards must be present at all times based off size, patron load, and features of the pool. Sheets were given out to staff. Staff then got lifeguard on duty.
Correction: Staff the pool with adequate numbers of properly-credentialed lifeguards and attendants.
Code ATCP 76.23(1)(a)1 - LIFEGUARDS OR ATTENDANTS PRESENT WHERE R
-
Serious
Critical
Corrected on site
GATES AND DOORS WHEN STAFFED
In a lifeguarded pool area: Gates and doors are not self-closing and latching, and the gates and doors to the pool are not staffed with an attendant and at least one lifeguard present. Pool was opened with no lifeguard present while a swimmer was in a pool over 2,000sqft. and sign was placed saying swim at your own risk. Discussed with staff that lifeguards must be present at all times based off size, patron load, and features of the pool. Sheets were given out to staff. Staff then got lifeguard on duty. Some of the emergency door we not self closing leading to the outside. One door could be opened from the outside. Staff is working on repairing doors. Lifeguard is on duty so this violation is corrected during inspection but staff is still working getting doors fixed.
Correction: Provide at least one attendant or lifeguard at the gate or door and at least one lifeguard, or close the pool and lock the gate or door until an attendant and lifeguard can be provided.
Code ATCP 76.34(4)(b)1. - ENTRY STAFFING IN LIEU OF GATES/DOORS
-
Not serious
Non-critical
Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.