Inspections
-
Jul 8, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE
Observed schedule 40 flowmeter installed on schedule 80 piping for the men's whirlpool.
Correction: Replace the schedule 80 piping with schedule 40 piping to allow for more accurate flowmeter readings.
Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
Observed operator has not developed and implemented a plan to minimize combined chlorine in the men's whirlpool.
Correction: Develop and implement a plan to minimize combined chlorine in the men's whirlpool
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
-
Oct 28, 2024 Routine · 9 non-critical, 1 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Observed weir door is missing. Instructed PIC to repair or replace missing weir door. PIC stated he will contact pool service company to install missing weir door.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Observed inlet eye balls are missing and inlets are point straight in towards th pool, not creating unfiorm distribution. Discussed with PIC on repairing or replacing missing inlet eye balls. PIC stated he will contact the pool service company to get replacement for missing inlets.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
STRAINER BASKET NOT CLEANED DAILY
Observed strainer baskets are not cleaned daily. Discussed with PIC about cleaning procedures of strainer baskets. PIC stated they clean strainer baskets twice a week. Instructed PIC to clean them daily.
Correction: Clean strainer baskets daily.
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
2 of the 3 flowmeters not being maintained in operating condition. Observed 1 of 2 pressures flowmeters and 1 digital are not operational. Discussed with PIC about flowmeters. PIC stated that they have a work order in and the flowmeters will be repair.
Correction: Adjust or repair the flowmeters.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded. Observed only half of the piping for the pump system is labled. Instructed PIC to lable all piping for pump system
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
Corrected on site
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 595 mV and water has not been tested manually. Instructed PIC to increase ORP and PIC adjusted to increase ORP. PIC was able to get ORP to 650.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone. No signage posted of emergency numbers and facility address. Instructed PIC to post sigane of emergency numbers and facility address. PIC is created and posted signage.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
Corrected on site
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted. Instructed PIC to have the maxium patron load posted in whirlpool area. PIC posted maxium patron load.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Above pool piping in pump room has a small leak. Instructed PIC to repair leaking pipe. PIC stated they will place a work order in with pool service company
Correction: Maintain the pool equipment piping.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
-
Nov 14, 2023 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition. Both the pressure and digital gauges are not functioning.
Correction: Adjust or repair the flow meters.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical