Inspections

  1. Mar 30, 2026 Routine · 7 non-critical
    • Serious Critical

      Air gaps, where required

      Observed an air gap is not installed on ice machine where the potential for contamination of the potable water supply exists. Instructed Person In Charge to provide an air gap on ice machine. PIC stated they will get an air gap on ice machine.

      Correction: Install an air gap on ice machine on 1st floor.

      Code ATCP 72.16(4)(c)

    • Serious Critical

      Smoke alarm maintained - working order; expiration

      Observed the smoke alarm in rooms 109, 115, 203, 222, 308, and 310 are expired. Could locate expiration on smoke alarms. Did investigations and looked up manufacturer and model of units in each of these rooms. Manufacturer is BRK Electronics and model is 4919 and the other is BRK Electronics model number is 100S. After investigation this models were discontinued between 2004-2007. Also observed yellowing of each unit. Instructed PIC to replace all expired smoke alarm. PIC stated they will replace all expire smoke alarms. PIC stated they will confirm that each bedroom that the alarms are not expire and if they are PIC will replace them.

      Correction: Repair or replace the smoke alarm within 5 calendar days.

      Code ATCP 72.18(11)(e)

    • Serious Critical

      Carbon monoxide alarm maintained - working order; expiration

      Observed the carbon monoxide alarm has not been replaced in accordance with the manufacturer’s date of expiration. Carbon monoxide detector was manufactered in 2013. Instructed PIC to replaced CO detector. PIC stated they will replace CO detector.

      Correction: Repair or replace the carbon monoxide alarm within 5 calendar days.

      Code ATCP 72.18(12)(h)

    • Not serious Priority Foundation

      Exit signs - indicates direction of travel

      Observed there is no exit sign provided with a directional indicator showing the direction of travel located to stair case in North West corner. Instructed Person In Charge to install a exit sign with direction of travel . Observed 1st and 3rd floor had all correct locations and were operational.

      Correction: Repair or replace the exit sign.

      Code ATCP 72.18(7)(b)3.

    • Not serious Non-critical

      DSPS building codes

      Observed boiler room and laundry room are not maintained according to the state building code as enforced by the Wisconsin department of safety and professional services. Observed in boiler room two pipes missing fire caulk. Instructed PIC to provide fire caulk to these areas. PIC stated they will get these areas fixed. Observed damaged walls in boiler room and in laundry. Observed a hole in ceiling in laundry room. Instructed PIC to repair these areas. PIC stated they will get these areas fixed.

      Correction: Contact the Wisconsin department of safety and professional services building construction section.

      Code ATCP 72.18(1)(a)

    • Not serious Non-critical

      Equipment and furnishings - maintained clean

      Observed the outside of nozzle of ice machines located on 1st and 2nd floor have accumulation of debris. Instructed PIC to increase cleaning frequency of these areas. PIC stated they will get these areas cleaned.

      Correction: All furnishings and equipment and shall be kept clean.

      Code ATCP 72.20(4)(a)

    • Not serious Non-critical

      Nonabsorbent mattress cover or mattress surface

      Observed the mattress of the sleeper sofas in rooms in 109, 203, and 310 are not provided with a nonabsorbent mattress protector that covers the entire sleeping surface. Observed each had a mattress pad but nonabsorbent. Instructed PIC to obtain nonaborbent mattress for each sleeper sofa. PIC stated they will get nonabsorbent mattress pads.

      Correction: Provide a nonabsorbent mattress protector that covers the entire sleeping surface or have an easily cleanable nonabsorbent mattress surface.

      Code ATCP 72.20(8)(d)

  2. Oct 2, 2024 Routine · 2 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Permit is not displayed conspicuously to the public. Permit is posted on wall behind lobby away from public view. Instructed Hotel Engineer to move permit to a location that is visible to the public.

      Correction: Post the permit in a conspicuous location to the public.

      Code ATCP 72.04 (7)

    • Not serious Non-critical

      PLUMBING CROSS-CONNECTIONS

      The following cross-connections have been identified: Ice machine discharge and floor drain pipe. Ice machine discharge pipe is inside the floor drain pipe. No visible air gap separates the two pipes. Instructed Hotel Engineer to provide an air gap at each ice machine discharge location.

      Correction: Provide an air gap or other approved backflow/backsiphonage protection device.

      Code [A] ATCP 72.10 (4)

  3. Oct 3, 2023 Routine · No items found

    No violations cited.