YearInspectionsViolationsSerious
20251101
2024132
2023100

Inspections

  1. Aug 19, 2025 Routine · 1 critical, 9 non-critical, 1 repeat
    • Not serious Non-critical Repeat Corrected on site

      LICENSE NOT POSTED

      Observed the license is not posted for public view. Informed pool operator. Pool operator then place license in public view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Observed there is no spare strainer or screen available for the pump. Instructed pool operator to have a spare strainer for the pump. Pool operator stated they wil get one.

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      Observed the recirculation (turnover) rate has not been met. Turnover rate is 6.3 hours. Instructed pool operator to have the tunrover rate 6 hours or less.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      PIPING LABELED, TAGGED OR CODED

      Observed the piping and valves for the skimmer and main drains is not labeled, tagged or color-coded. Instructed pool operator to label them. Pool operator stated they would label them.

      Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.

      Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED

    • Not serious Non-critical

      DOORS

      Observed doors to chemical storage areas are locked but are not marked to indicate entry is for authorized personnel only. Instructed pool operator to label doors for chemical storage with authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      ALKALINITY

      Observed the total alkalinity is at 40ppm. Informed pool operator and pool operator stated they will get this corrected.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      FIRST AID KIT -RESUSCITATION POCKET MASK

      Observed the first aid kit is missing a resuscitation pocket mask. Instructed pool operator to have a resuscitation pocket mask in first aid kit. Pool operator stated they will get one.

      Correction: Provide a resuscitation pocket mask for the first aid kit.

      Code ATCP 76.27(1)(b)8.- RESUSCITATION MASK

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Observed two emergency blankets in good condition are not available in the pool area. Pool operator stated they had purchased two and now they are missing. Pool operator stated they would get two more.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Observed the pool deck area not maintained in good repair. Observed areas of the concrete is chipping off or is cracking. Pool operator is aware of issue and stated it will get fixed.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      WATER SUPPLY PROTECTION

      Observed approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool. Observed no air gap provided on backwashing pipe then leads into sewer drain. Instructed pool operator to install an air gap. Pool operator stated they will get an air gap on the backwashing pipe.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

  2. Jul 29, 2024 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      The license is not posted for public view. Discussed with staff placing permits in an area that can be viewed by the public. Staff will post permit in the main office for public to view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Serious Critical Corrected on site

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working. Office phone is operational, however it can only be accessed during Office hours. Deck emergency phone was not operational. Discussed with staff installing an operational emergency phone. Staff installed a new phone which was tested and deemed operational.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. Pool gate does not self close or latch. Discussed with staff installing a self closing mechanim and a self latching mecanism for the pool gate. In the meantime, staff will keep pool open same hours as Office and patrons will access and exit the pool through the Office.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

  3. Jun 26, 2023 Routine · No items found

    No violations cited.

Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.