Inspections
-
Aug 6, 2024 Routine · 2 critical, 11 non-critical
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view. License posted inside lifeguard station unavailable for public view. Instructed Pool Manager to post license in an area visible to the public.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
GUTTER POOLS RECIRCULATION FLOW
Proportion of water flow recirculating from gutter and main drain is 100% each. Instructed Pool Manager to adjust circulation of valves to achieve approximately 75% of the required recirculation flow through the gutter and 25% from the main drain.
Correction: Adjust equipment so that proportion of water flow recirculating from gutter and main drain is mostly from gutter.
Code ATCP 76.11(2)(a) 2. a. - GUTTER POOLS RECIRCULATION FLOW
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Pool is recirculating every 7.8 hours. Instructed Pool Manager to adjust rate to a maximum of 6 hours. .
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of maximum 6 hours. .
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
DOORS
Doors to chemical storage areas not marked to indicate entry is for authorized personnel only. Instructed Pool Manager to mark door with a sign indicating entry restriction to Authorized Personnel Only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for a pool chemicals including calcium hypochorite, conditioners, pH balancers, and acid. Instructed Pool Manager to provide physical copies of safety data sheet for each pool chemical.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 432 mV and water has not been tested manually. Instructed Pool Manager to keep water potential above 650 mV and below 850 mV.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED
No lifeguard and attendant staffing plan is available. Instructed Pool Manager to make a staffing plan available.
Correction: Prepare and maintain a lifeguard staffing plan.
Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR
-
Not serious
Non-critical
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone. Instructed Pool Manager to provide signage near the phone indicating emergency numbers and facility address. Pool Manager provided signage of emergency numbers and facility address. Pool Manager also posted the signage near emergency phone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available. Instructed Pool Manager to provide biohazard safety equipment that includes blood and biohazard disposal kit to be placed at the Lifeguard station or near the pool.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Pool basin displays chipping in one area of the basin wall. Instructed Pool Manager to repair chipping. Pool Manager is aware of the issue and has scheduled repair and resurfacing of the basin this month.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
WATER HEATERS-MAINTAINED OPERATIONAL
Water heater not in operating condition. Water heater was out of service during the inspection. Instruce Pool Manager to maintain heater in operating condition. Pool Manager stated heater will be serviced this week.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Serious
Critical
CERTIFICATION MADE AVAILABLE, LIFEGUARD
A copy of each certification held by a lifeguard has not been made available to the department or its agent. Office staff in charge of certifications is currently out of the office until tomorrow. Instructed Pool Manager to make Lifeguard certifications available.
Correction: Make a copy of each certification held by a lifeguard available to the department or its agent.
Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the drain cover specifications. Instructed Pool Manager to provide manuals for VGBA cover that includes curve and drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.