Village Of Pleasant Pr:recplex
9900 TERWALL TER, Pleasant Prairie, WI 53158 · Kenosha County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Kenosha County Division of Health
- License / ID
- NFRY-8XQ4GJ
- Status
- Permitted
- Phone
- (262) 947-0437
- Official record
- Kenosha County Division of Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2024 | 3 | 22 | 4 |
Inspections
-
Nov 12, 2024 Routine · 1 critical, 7 non-critical, 1 repeat
-
Not serious
Non-critical
LICENSE NOT POSTED
Observed the whirlpool license is not posted for public view. Instructed manager to post the whirlpool license for public view. Manager will post whirlpool license.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
Corrected on site
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Observed one of two weir doors were missing. Discussed with pool manager. Pool manager was able to get another weir door and installed it.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
Observed the water potential ("ORP") is 488 mV and water has not been tested manually. Instructed pool manager to increase the ORP to be between 650-900 mv. Pool manager is going to increase ORP.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
POOL RULES SIGNAGE- COMMUNICABLE DISEASE
Observed whirlpool pool rules missing rule: Do not enter the pool if you have a communicable disease or an open cut. Instructed pool manager to add the missing whirlpool rule. Manager is going to had missing whirlpool rule.
Correction: Include pool rule on sign: Do not enter the pool if you have a communicable disease or an open cut.
Code ATCP 76.29(1)(b)1.a - NO COMMUNICABLE DISEASE, OPEN CUT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Observed signage or other communication warning against prolonged breath-holding is not posted or otherwise provided. Dicussed with pool manager. Pool manager stated sign were removed when walls of the whirlpool area was repainted. Manager will have the prolonged breath-holding sign posted.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
SHOWERS-OPERABLE
Showers not maintained in an operable condition. Observed in the male designated locker room that the ADA shower is not operation. Discussed with pool manager and pool manager has a work order already placed.
Correction: Maintain showers in an operable condition.
Code ATCP 76.33 (2)(b) - SHOWERS OPERABLE
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Observed that the equalizer covers for the skimmers in whirlpool have expired. Instructed pool manager to replaced expired equalizer covers. Manager is going to place a work order in to get replacement equalizer covers and intsall them..
Correction: Maintain the whirlpool equalizer cover.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
Corrected on site
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close. Observed the two doors that lead to the outside not self-closing. Informed pool manager and pool manager had employee fix the two doors. Doors are now self closing.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
-
Apr 12, 2024 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weirs door are missing from skimmer. Disucssed with staff that all skimmmers need to have a weir door or a floating weir..
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available. One skimmer was missing it strainer basket. Disucssed with staff that all skimmer need to have strainer baskets.
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
-
Apr 8, 2024 Routine · 3 critical, 9 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weirs door are missing from skimmer. Disucssed with staff that all skimmmers need to have a weir door or a floating weir..
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available. One skimmer was missing it strainer basket. Disucssed with staff that all skimmer need to have strainer baskets.
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
STRAINER BASKET NOT CLEANED DAILY
Strainer baskets are not cleaned daily. Staff informed me strainer baskets are cleaned weekly. Discussed with staff that strainer must be cleaned daily.
Correction: Clean strainer baskets daily and have a clean strainer being operating.
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40ppm. Discussed with staff that alkalinity needs to be 60ppm
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a whirlpool and pool water is not tested at least twice a week for the combined chlorine level. Staff is not testing a combined chlorine twice a week. Discussed with staff that combined chlorine must be tested twice a week.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirlpool water not tested at least once a week for total alkalinity. Staff is not testing alkalinity once a week. Disucssed with staff on testing alkinity once a week.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
Corrected on site
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality pursuant. Whirlpool was openned when it was recorded on daily log free chlorine was below 3ppm. Discussed with staff on closing criteria and sanitizer levels. Whirlpool is closed and staff is increasing free chlorine levels. Staff raised the free chlorine and is testing at 5.6ppm..
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone. No sign posted with emergency numbers listed. Disucssed with staff on placing sign with emergency contacts near each phone..
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. VGBA Grate is missing a screw. Discussed with staff on repairing or replacing screw for VGBA grate.
Correction: Maintain the pool equipment VGBA grate screw .
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 2ppm for chlorine in whirlpool. Discussed with staff that whirlpool is closed until it reaches 3ppm. Staff raised the free chlorine and is testing at 5.6ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together. Shepherd's crook head is off from pole. Disucssed with staff on repairing or replacing sheperd's crook. Staff was able to fix shepherd's crook.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
Corrected on site
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. All telephones in pool area were remvoed from their box or not working. Disucssed with staff on replacing or repairing telephones in pool area. Staff were able to fix and put a phone in pool area.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.