Market Square Apartments, LLC
3100 MARKET LN, Kenosha, WI 53144 · Kenosha County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Kenosha County Division of Health
- License / ID
- LWET-CUJHUH
- Status
- Permitted
- Phone
- (833) 966-1854
- Official record
- Kenosha County Division of Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 2 |
| 2025 | 2 | 11 | 2 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Jul 29, 2026 Routine · 2 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
Observed the flowmeter for the recirculation pump is not operational and shows no gpm flow reading. Observed the psi gauge for the filter is not operational and the needle for the gauge is flipped around the gauge so it would not read correctly. Informed the responsible supervisor that both the flow meter and the filter psi gauge must be repaired.
Correction: Repair the flowmeter for the recirculation pump and repair the psi gauge for the filter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
Observed no backwash procedure posted in the pool room. The responsible supervisor also informed they did not have a set procedure for backwashing at a certain psi. The responsible supervisor was informed to create a backwash procedure set psi and display it on an easily readable chart following the filter manufacturer directions.
Correction: Create a backwash procedure and set backwash psi and display it on an easily readable chart following the filter manufacturer directions.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
DOORS
Observed the doors to the pool control room where the chemicals are stored were locked and only accessible to maintenance personnel, including the responsible supervisor for the pool. The pool control room was not marked for authorized personnel only.
Correction: Mark the pool control room in some way that states entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Observed the establishment uses a Taylor K-2006C test kit. Observed expired R-0870 reagent with an expiration of 01-2026. There were other observed expired reagents, however, those reagent are typically not used as part of the operating log for pools with controllers. The responsible supervisor informed that they will order a new test kit as they wanted to get a new set of supplies anyways.
Correction: Discard expired reagents, and replace with appropriate reagents by the manufacturer for the used test kit.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Serious
Critical
RESPONSIBLE SUPERVISOR SANITATION AND TESTING
Observed no daily operating log books available indicating the responsible supervisor is regularly testing the sanitation of the pool. The responsible supervisor informed that they recently took on the role of pool responsible supervisor within this past month and have not been testing the pool as frequently as required. The responsible supervisor was informed of testing requirements for the pool and was provided with an operating log for pools with controllers sheet.
Correction: Begin regularly testing the pool according to the operating log for pools with controllers sheet provided.
Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel burning pool heater in the pool equipment room. There was no observe CO alarm in the pool equipment room. The responsible supervisor was informed that the pool equipment room will need a CO alarm. The responsible supervisor had another employee go and place a CO alarm in the pool room.
Correction: Place a CO alarm in the pool equipment room where there is a fuel burning pool heater.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jun 11, 2025 Re-inspection · 3 non-critical, 2 repeat
-
Not serious
Non-critical
TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY
Observed emergency phone does have connection to permanent power supply but not theft protection. Observed phone can be removed from power supply. Informed Pool operator and pool operator stated they are going to install theft protection.
Correction: Provide a connection to permanent power supply.
Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
Observed the pressure gauge coming from the pipe after the pump is filled with water and is not being maintained in operating condition. Gauge is not operational. PIC is aware if the issue and has a work order in.
Correction: Adjust or repair the pump gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Observed pool deck area not maintained in good repair. Observed areas of the concrete where it is chipping and missing some pieces. Informed PIC and PIC stated they will repair those areas.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
-
Jun 2, 2025 Routine · 2 critical, 6 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Observed 1 of 2 weirs are missing from the skimmers. Informed PIC and PIC from the weir and installed it.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Observed the inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Observed inlets are facing in towards the pool. Instructed person in charge to have all inlets facing the same directions. PIC stated they will makesure all inlets are facing the same direction.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
Observed the pressure gauge coming from the pipe after the pump is filled with water and is not being maintained in operating condition. Gauge is not operational. PIC is aware if the issue and has a work order in.
Correction: Adjust or repair the pump gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
REAGENTS REPLACED
Observed test kit reagents not replaced as recommended by the manufacturer. Observed several reagents are expired. Informed PIC and PIC is going to order new test kit.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
EMERGENCY BLANKETS
Observed two emergency blankets in good condition are not available in the pool area. Instructed PIC to have two emegency blankets. PIC stated they will get two emergency blankets.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Observed pool deck area not maintained in good repair. Observed areas of the concrete where it is chipping and missing some pieces. Informed PIC and PIC stated they will repair those areas.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
MAXIMUM CHLORINE
Observed the maximum chlorine residual exceeds 10 ppm. Test and informed PIC of findings. Conducted another test and showed PIC the results. PIC unable to test pool due to reagents being expired. PIC then closed the pool.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Serious
Critical
TELEPHONE ACCESSIBLE
Observed a telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Push button emergency phone is not operational. Informed PIC and PIC has closed the pool. PIC stated they will fix the push button or get a new one phone.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
Corrected on site
-
Aug 9, 2023 Pre-inspection · No items found
No violations cited.
Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.