Springhill Suites Kenosha
7653 125TH AVE, Kenosha, WI 53142 · Kenosha County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Kenosha County Division of Health
- License / ID
- BWOK-BVYKZW
- Status
- Permitted
- Phone
- (262) 930-9778
- Official record
- Kenosha County Division of Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2024 | 3 | 16 | 4 |
Inspections
-
Oct 18, 2024 Routine · 3 non-critical
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available. No biohazard kit available. Instructed Manager to provide biohazard kit.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POOL RULES SIGNAGE- COMMUNICABLE DISEASE
Pool rules missing rule: Do not enter the pool if you have a communicable disease or an open cut. Instructed Manager to ammend rules to include access restriction to people with commicable disease or an open cut.
Correction: Include pool rule on sign: Do not enter the pool if you have a communicable disease or an open cut.
Code ATCP 76.29(1)(b)1.a - NO COMMUNICABLE DISEASE, OPEN CUT
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present. Posted rules state adult supervision for children under age 14. Instructed Manager to ammend posting in order to restrict access to children under age 12.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
-
Mar 22, 2024 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Inlets covers and inlets directional eyes are missing. Discussed with staff on replacing screw and replacing inlets covers and inlet directional eyes.
Correction: Maintain the pool equipment inlets covers. and inlet directional eyes.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
-
Mar 12, 2024 Routine · 4 critical, 8 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir doors are missing from skimmer. Disucssed with staff on replacing skimmer with weir door or floating weir.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Inlets are facing in towards the pool and not in same direction and not creating uniform distribution pattern. Discussed with staff inlets must be flowing the same dricetion creating uniform distribution.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
STRAINER BASKET NOT CLEANED DAILY
Strainer basket not cleaned daily. Strainer basket had debris in it and staff informed me that baskets were not cleaned today. Informed staff strainer baskets need to be cleaned daily and must be clean before openning the pool.
Correction: Clean strainer basket daily and before openning pool.
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 640 mV and water has not been tested manually. Discussed with staff ORP mus be between 650-900
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Some of the reagents have expired. Discussed with staff on replacing expire reagents.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Pool was openned today and staff did not test pool chemistry. Discussed with staff that pool must be tested before openning.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted. Current sign in pool area does not have maxium patron load. Disucssed with staff on updating maxium patron load on sign.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Inlets covers and inlets directional eyes are missing. Discussed with staff on replacing screw and replacing inlets covers and inlet directional eyes.
Correction: Maintain the pool equipment inlets covers. and inlet directional eyes.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
Corrected on site
RESPONSIBLE SUPERVISOR FOR POOL
The pool does not have a responsible supervisor. Staff openned the pool without testing the pool chemistry, emergency phone was not properly operating, VGBA grate was missing a screw and shepard's crook was broken. Discussed with staff and manager the issues. Issues are currently being corrected.
Correction: Provide a responsible supervisor for the pool.
Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED
-
Serious
Critical
Corrected on site
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together. Crook part of the shepards crook is broken and not secured down to the pole. Crook fell off the pole when testing the length of the pool to reach deepest part of pool. Discussed with staff that shepherd's crook must be replaced or repaired. Staff fixed shepherd's crook and operational.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected. Staff fixed shepherd's crook.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
Corrected on site
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Phone was not operating and count not dial out. Disucssed with staff phone needs to be repaired or replaced. Staff replaced phone and new phone works.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. Staff replaced phone and new phone works.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
Corrected on site
HAZARDOUS CONDITION
There is a hazardous condition at the pool. VGBA grate is missing a one of the four screws. Disucssed with staff on replacing screw. Staff installed new screw.
Correction: Correct the hazardous condition install new screw for VGBA grate. Staff installed new screw.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.