RecordWell Data

Club At Strawberry Creek, The

14810 72ND ST, Kenosha, WI 53142 · Kenosha County

6cited violations
3serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Kenosha County Division of Health
License / ID
NFRY-8XQ4GB
Status
Permitted
Phone
(262) 857-8400 ext. 107
Official record
Kenosha County Division of Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025131
2024132
2023100

Inspections

  1. Jun 24, 2025 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      Observed the water potential ("ORP") is 631mV. PoolBlu was also onsite and is aware of the ORP being low. PoolBlu is currently working on raising ORP.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      WATER ATTRACTOIN MAINTENANCE AND REPLACE OR REPAIR

      Defective, improper, worn, or missing parts have not been replaced or repaired. Observed some of the non-slip textured strips are showering wear and strips are missing some pieces. PIC aware of the non-slip textured strisp. PIC stated they will get them repaired. Also observed paint chipping from the tongue of the frog water slide. PIC aware of the chipping paint and stated they will get it repaired.

      Correction: Replace or repair defective, improper, worn, or missing parts.

      Code ATCP 76.37(1)(c)1. - PARTS REPLACED

    • Serious Critical Corrected on site

      HAZARDOUS CONDITION

      Observed there is a hazardous condition at the pool. Observed a screw missing from from the VGBA grate. Informed PIC and PoolBlu. PoolBlu then place a screw in the grate. Grate is in complaince

      Correction: Correct the hazardous condition.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

  2. Jun 28, 2024 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. Water was not moving vigorously. Discussed with staff on having the skimmers adjusted.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Serious Critical Corrected on site

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. VGBA grates had wrong and wrongly placed screws.PoolBlu put correct screws in the correct location and vertified and stated they were secured.

      Correction: Correct the hazardous condition.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical Corrected on site

      GATES AND DOORS WHEN STAFFED

      In a lifeguarded pool area: Gates and doors are not self-closing and latching, and the gates and doors to the pool are not staffed with an attendant and at least one lifeguard present. Attendant left post then returned .

      Correction: Provide at least one attendant or lifeguard at the gate or door and at least one lifeguard, or close the pool and lock the gate or door until an attendant and lifeguard can be provided.

      Code ATCP 76.34(4)(b)1. - ENTRY STAFFING IN LIEU OF GATES/DOORS

  3. Jun 5, 2023 Routine · No items found

    No violations cited.

Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.