  1. Jul 23, 2026 Routine · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      Observed operator does not have a dedicated developed and implemented plan to minimize combined chlorine in the pool. CPO informed they have instructions from pool operating books how to manage combined chlorine. CPO informed he monitors and manages combined chlorine. Instructed CPO to develop and implement a plan to minimize combined chlorine in the pool. CPO provided with DATCP combined chlorine management template form.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

  2. Aug 18, 2025 Routine · 2 critical, 4 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Observed there are no spare strainers baskets or screens available for the skimmers. Instructed Certified Pool Operator to get extra skimmer baskets. CPO stated they would get extras.

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Corrected on site

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      Observed flowmeter float is stuck and is not being maintained in operating condition. Informed CPO and CPO corrected it and is operational.

      Correction: Adjust or repair the flowmeter float.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      Observed the operator has not developed and implemented a plan to minimize combined chlorine in the pool. Provided education to CPO. CPO stated they would create an combined chlorine plan.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      Observed filter tank is not properly maintained and has a leak. Instructed CPO to repair leak on filter tank. CPO stated they would get it fixed.

      Correction: Maintain the pool equipment filter tank.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical Corrected on site

      WATER SUPPLY PROTECTION

      Observed approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point. Instructed CPO to have an air gap from backwashing pipe to the sewer drain. CPO then cut pipe into complaince creating an air gap.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

    • Serious Critical Corrected on site

      CO ALARM-POOL EQUIPMENT ROOM

      Observed there is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room. Instructed CPO to have a CO alarm in pump room with the fuel burning appliance. CPO installed CO alarm.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  3. Aug 7, 2024 Routine · 1 critical
    • Serious Critical

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. One of the pool gates is not self-closing. Instructed CPO to ensure gate self-closes. CPO will schedule gate service and in the meantine, will place a sign instructing patrons not to use gate .

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

Source: Kenosha County Division of Health. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.