Americinn By Wyndam Tomahawk.

108 W MOHAWK DR, Tomahawk, WI 54487 · Lincoln County

21cited violations
6serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Lincoln County Health Department
License / ID
MMAI-DG9KW9
Status
Permitted
Phone
(715) 301-0650
Official record
Lincoln County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20253216

Inspections

  1. Nov 25, 2025 Re-inspection · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer weir doors are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 295 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Most of the reagants present are expired. Many of the reagants that appear to be in use are for chlorine, not bromine.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      The facility address is faded on the sign posted.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

  2. Nov 24, 2025 Routine · 5 critical, 9 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer weir doors are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 295 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Most of the reagants present are expired. Many of the reagants that appear to be in use are for chlorine, not bromine.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Records show that the pools were last tested on 11.20.2025.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      OPERATOR RESPONSIBILITIES

      The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.

      Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.

      Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES

    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      The facility address is faded on the sign posted.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing 11.22 - 11.24.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED

      The women's shower, toilet room is out of order at time of inspection. Sign posted directs guests to lobby restroom. Water leak/damage to ceiling observed. The shower floor in the men's restroom has a large crack in it.

      Correction: Maintain the shower, toilet and dressing facilities in good repair.

      Code ATCP 76.33 (2)(a)1. - GOOD REPAIR

    • Not serious Non-critical

      AIR MOVEMENT

      Condensation observed on ceilings and around windows.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.80 for bromine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      RESPONSIBLE SUPERVISOR FOR POOL

      The pool does not have a responsible supervisor. No responsible supervisor is present at time of inspection. PIC indicated that night audit tests the pool in the absence of the regular supervisor.

      Correction: Provide a responsible supervisor for the pool.

      Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO MEET 76.16

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. Bromine is 0.80 PPM

      Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16.

      Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16

    • Serious Critical

      CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR

      The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.

      Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.

      Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR

    • Serious Critical

      GATES AND DOORS EXIT

      The emergency exit does not open.

      Correction: Provide an exit from the pool enclosure that does not require a key, punch code, or electronic method to exit a pool enclosure.

      Code ATCP 76.34(4)(a)(1m)(d)- EXIT UNRESTRICTED

  3. May 1, 2025 Pre-inspection · 1 critical, 2 non-critical
    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 510 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Serious Critical

      GATES AND DOORS MAINTAINED

      Gate or door has not been maintained for proper operation. Door catches on floor.

      Correction: Maintain the gate or door for proper operation.

      Code ATCP 76.34(2)(a) - GATES AND DOORS OPERABLE

Source: Lincoln County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.