YearInspectionsViolationsSerious
20263185
20243177
2023373

Inspections

  1. Jan 30, 2026 Admin Follow Up · 2 critical, 5 non-critical, 3 repeat
    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-INSTALLATION DATE

      The VGBA log or other proof does not indicate drain cover installation date.

      Correction: Indicate in the log of drain cover installation date.

      Code ATCP 76.38(2)(b)5. - INSTALL DATE

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 475 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Serious Critical

      Modification(s) made but no DSPS Approval available for them.

      The operator modified the pool basin at some point between 2013 and 2026 and did not submit pool construction plans to DSPS for review and approval.

      Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.

      Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  2. Jan 14, 2026 Re-inspection · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 475 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

  3. Jan 13, 2026 Routine · 3 critical, 6 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 535 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY INSTALLLED

      The main drain is missing screws.

      Correction: Close the Pool. Ensure that the pool equipment is properly installed.

      Code ATCP 76.33(1)(e)2. - INSTALLATION OF POOL EQPT.

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      PH

      The pH is 8.2 (WaterLink Spin Touch), 8.0 (HANNA pH Meter)

      Correction: Close the Whirlpool. Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm. WaterLink SpinTouch reading of 14.70 PPM.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical Corrected on site

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. The pH exceeds 7.8 PPM. The Chlorine exceeds 10 PPM. .

      Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

  4. Dec 27, 2024 Routine · 5 critical, 5 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in a Whirlpool and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical Corrected on site

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      WHIRLPOOL WATER TEMPERATURE

      The whirlpool water temperature is 109°F using a calibrated probe thermometer.

      Correction: Maintain the whirlpool water at greater than 90°F or 32°C, and may not exceed 104°F or 40°C.

      Code ATCP 76.19(4)(c) - WHIRLPOOL WATER TEMP

    • Serious Critical

      RESPONSIBLE SUPERVISOR POOL CLOSED

      Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. Emergency Phone is not functioning.

      Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria.

      Code ATCP 76.21 (1)(c)10. - CLOSE POOL

    • Serious Critical

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  5. Dec 27, 2024 Follow Up · 2 critical, 4 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in a Whirlpool and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Repeat

      WHIRLPOOL WATER TEMPERATURE

      The whirlpool water temperature is 109°F using a calibrated probe thermometer.

      Correction: Maintain the whirlpool water at greater than 90°F or 32°C, and may not exceed 104°F or 40°C.

      Code ATCP 76.19(4)(c) - WHIRLPOOL WATER TEMP

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  6. May 2, 2024 Re-inspection · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

  7. Jul 20, 2023 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      VENTILATION NOT EFFECTIVELY VENTING

      Ventilation in the chemical storage room and pump room requires a professional inspection and repair. A referral has been made to DSPS.

      Correction: Repair the ventilation system to prevent condensation and air quality problems.

      Code ATCP 76.33(4)(b)

    • Serious Critical Repeat

      SELF-CLOSING AND LATCHING GATES

      The door or gate to the pool enclosure is not latching. Additionally, the door to the outside was propped open.

      Correction: Repair the door immediately so that it is self-closing and latching.

      Code [A] ATCP 76.34(4)

  8. Jul 17, 2023 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      VENTILATION NOT EFFECTIVELY VENTING

      Ventilation in the chemical storage room and pump room requires a professional inspection and repair. A referral has been made to DSPS.

      Correction: Repair the ventilation system to prevent condensation and air quality problems.

      Code ATCP 76.33(4)(b)

    • Serious Critical Repeat

      SELF-CLOSING AND LATCHING GATES

      The door or gate to the pool enclosure is not latching. Additionally, the door to the outside was propped open.

      Correction: Repair the door immediately so that it is self-closing and latching.

      Code [A] ATCP 76.34(4)

  9. Jul 12, 2023 Routine · 1 critical, 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      CHEMICAL STORAGE

      Chemicals are not stored in accordance with ATCP 76.12(2). Chemicals are stored in pans insuffucuent in size to contain a leaking container. Other quantities of pool chamicals are stored in the same room on the floor which could react with the chlorine. residues of evaporated chlorine were observed on the containers and pans.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Non-critical

      VENTILATION NOT EFFECTIVELY VENTING

      Ventilation in the chemical storage room and pump room requires a professional inspection and repair. A referral has been made to DSPS.

      Correction: Repair the ventilation system to prevent condensation and air quality problems.

      Code ATCP 76.33(4)(b)

    • Serious Critical Repeat

      SELF-CLOSING AND LATCHING GATES

      The door or gate to the pool enclosure is not latching. Additionally, the door to the outside was propped open.

      Correction: Repair the door immediately so that it is self-closing and latching.

      Code [A] ATCP 76.34(4)