RecordWell Data

Dhpi Land LLC #2

N10374 RED ARROW LN, Tomahawk, WI 54487 · Lincoln County

11cited violations
5serious tier
5inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Lincoln County Health Department
License / ID
MYOG-9VCP2A
Status
Permitted
Phone
(920) 866-9001
Official record
Lincoln County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262115
2025100
2024100
2023100

Inspections

  1. Jun 12, 2026 Admin Follow Up · 3 non-critical, 3 repeat
    • Serious Critical Repeat

      General health and safety standard

      In the back, right corner of the garage, there is an electrical box and gas line hanging. The electrical box is unsecured, missing a cover plate and has a wire extended from the box. The gas piping is uncapped and unsupported. Electrical and gas line are zip tied together. The ventilation vents to the outside and is not a concern at this time.

      Correction: Secure the gas line and cap the open pipe. Secure the electrical box, install a cover plate and secure open wire. Work with a licensed professional to ensure installations are code compliant.

      Code ATCP 72.15

    • Not serious Priority Foundation Repeat

      Handrail on stairs > 3 risers

      The stairs off the deck are not provided with a handrail.

      Correction: At least one handrail shall be provided for a flight of stairs with more than 3 risers.

      Code ATCP 72.18(2)(a)1.

    • Not serious Priority Foundation Repeat

      Guards provided on stairs > 3 risers

      Guards are not provided on all open sides of the outside deck stairs.

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers.

      Code ATCP 72.18(2)(b)1.

  2. May 28, 2026 Routine · 8 non-critical
    • Serious Critical

      General health and safety standard

      In the back, right corner of the garage, there is an electrical box and gas line hanging. The electrical box is unsecured, missing a cover plate and has a wire extended from the box. The gas piping is uncapped and unsupported. Electrical and gas line are zip tied together. The ventilation vents to the outside and is not a concern at this time.

      Correction: Secure the gas line and cap the open pipe. Secure the electrical box, install a cover plate and secure open wire. Work with a licensed professional to ensure installations are code compliant.

      Code ATCP 72.15

    • Serious Critical

      Smoke alarms provided

      Smoke alarm is not provided in the basement outside of the sleeping room.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided in the basement sleeping room connected to the utility room containing fuel burning hot water heater and furnace.

      Correction: Provide carbon monoxide alarms at the locations specified in rule.

      Code ATCP 72.18(12)(a)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      The basement sleeping room is connected to the utility room where the fuel burning furnace and hot water heater are located. A carbon monoxide alarm is not provided in the sleeping room. A carbon monoxide alarm is provided outside of the bedroom as required.

      Correction: Provide a carbon monoxide alarm in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The basement does not have a smoke alarm outside of the sleeping area.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Handrail on stairs > 3 risers

      The stairs off the deck are not provided with a handrail.

      Correction: At least one handrail shall be provided for a flight of stairs with more than 3 risers.

      Code ATCP 72.18(2)(a)1.

    • Not serious Priority Foundation

      Guards provided on stairs > 3 risers

      Guards are not provided on all open sides of the outside deck stairs.

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers.

      Code ATCP 72.18(2)(b)1.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  3. May 12, 2025 Routine · No items found

    No violations cited.

  4. Apr 29, 2024 Routine · No items found

    No violations cited.

  5. Jun 19, 2023 Routine · No items found

    No violations cited.

Source: Lincoln County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.