RecordWell Data

Half Moon Hideaway

N11201 STONE RD, Tomahawk, WI 54487 · Lincoln County

8cited violations
3serious tier
6inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Lincoln County Health Department
License / ID
MMAI-CHKJBX
Status
Permitted
Phone
(630) 709-6126
Official record
Lincoln County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026383
2025100
2024100
2023100

Inspections

  1. Aug 31, 2026 Admin Follow Up · No items found

    No violations cited.

  2. Aug 11, 2026 Admin Follow Up · 3 non-critical, 3 repeat
    • Serious Critical Repeat

      Backflow prevention devices, where required

      A backflow or back siphonage prevention device is not installed on the outdoor spigot near the shed where the potential for contamination of the potable water supply exists.

      Correction: Install an [ASSE 1011/ASSE 1052]-[threaded hose connection] compliant backflow or back siphonage prevention device on the spigot near the shed.

      Code ATCP 72.16(4)(b)

    • Not serious Priority Foundation Repeat

      Guard spacing <= 6"

      The space between guards is more than 6 inches for the front door stair railing for three of the gaps.

      Correction: Modify the space between guards to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation Repeat

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  3. Jul 30, 2026 Routine · 5 non-critical
    • Serious Critical

      Backflow prevention devices, where required

      A backflow or back siphonage prevention device is not installed on the outdoor spigot near the shed where the potential for contamination of the potable water supply exists.

      Correction: Install an [ASSE 1011/ASSE 1052]-[threaded hose connection] compliant backflow or back siphonage prevention device on the spigot near the shed.

      Code ATCP 72.16(4)(b)

    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not provided within each individually keyed unit and in required locations.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. Both bedrooms do not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Guard spacing <= 6"

      The space between guards is more than 6 inches for the front door stair railing for three of the gaps.

      Correction: Modify the space between guards to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  4. Aug 14, 2025 Routine · No items found

    No violations cited.

  5. Aug 27, 2024 Routine · No items found

    No violations cited.

  6. Aug 23, 2023 Routine · No items found

    No violations cited.

Source: Lincoln County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.