Cobblestone Inn & Suites
3209 E MAIN, Merrill, WI 54452 · Lincoln County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Lincoln County Health Department
- License / ID
- MMAI-CQMR5T
- Status
- Permitted
- Phone
- (312) 522-3490
- Official record
- Lincoln County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 6 | 1 |
| 2024 | 4 | 22 | 4 |
Inspections
-
Nov 24, 2025 Follow Up · No items found
No violations cited.
-
Nov 20, 2025 Routine · 1 critical, 5 non-critical, 1 repeat
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. All reagants expired within the past year.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
The facility address is not attached or posted near the emergency telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
FIRST AID KIT -RESUSCITATION POCKET MASK
The first aid kit is missing a resuscitation pocket mask.
Correction: Provide a resuscitation pocket mask for the first aid kit.
Code ATCP 76.27(1)(b)8.- RESUSCITATION MASK
-
Not serious
Non-critical
Corrected on site
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
Corrected on site
DRINKING FOUNTAIN MAINTAINED
The drinking fountain was off at time of inspection. Corrected during inspection - water was unintentionally turned off.
Correction: Maintain the drinking fountain in clean and sanitary condition.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Serious
Critical
Corrected on site
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
Emergency phone hook switch sticks, creating an unreliable service connection. Corrected During Inspection - Replaced phone during inspection.
Correction: Provide a reliable service connection for the communication technology.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Not serious
Non-critical
-
Dec 18, 2024 Re-inspection · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer weirs are in disrepair. Floating weir was upside down.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The hinge screws are stripped from the door to the men's restroom/shower.
Correction: Maintain the shower, toilet and dressing facilities in good repair.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Not serious
Non-critical
Repeat
ELECTRICAL GOOD REPAIR
Electrical outlet to the right of the drinking fountain shows evidence of melting/burning. Electrical outlet box below the No Lifeguard sign is not secure.
Correction: Maintain electrical equipment in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Not serious
Non-critical
Repeat
-
Dec 17, 2024 Routine · 2 critical, 6 non-critical, 1 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer weirs are in disrepair. Floating weir was upside down.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The hinge screws are stripped from the door to the men's restroom/shower.
Correction: Maintain the shower, toilet and dressing facilities in good repair.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Not serious
Non-critical
ELECTRICAL GOOD REPAIR
Electrical outlet to the right of the drinking fountain shows evidence of melting/burning. Electrical outlet box below the No Lifeguard sign is not secure.
Correction: Maintain electrical equipment in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.
Correction: Close the pool in the event of a nonfunctional emergency phone.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Not serious
Non-critical
-
Mar 26, 2024 Follow Up · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Inspector to send template.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. All reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.The first aid kit shall contain all of the following items: Pf 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
-
Mar 22, 2024 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Inspector to send template.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. All reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.The first aid kit shall contain all of the following items: Pf 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Serious
Critical
CHEMICAL STORAGE ACCESS RESTRICTED
Chemical storage area access not restricted to authorized personnel. Door does not latch shut.
Correction: Restrict access to chemical storage area to only authorized personnel.
Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED
-
Serious
Critical
Corrected on site
GATES AND DOORS-LATCHING
The emergency exit door is not self-latching.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
Source: Lincoln County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.