| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2025 | 2 | 6 | 3 |
| 2024 | 1 | 16 | 2 |
Inspections
-
Jun 2, 2026 Routine · 1 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
-
Jun 5, 2025 Follow Up · No items found
No violations cited.
-
Jun 4, 2025 Routine · 3 critical, 3 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 20.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
WALLS, CEILINGS, FLOORS
The walls, ceilings and floors in a pool area have not been maintained in clean and sanitary condition. The pool deck surrounding the diving board and along the walls and edges are littered with debris and need additional cleaning
Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition.
Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS
-
Serious
Critical
PH
The pH is less than 6.8.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
CPR/AED CERTIFICATION, LIFEGUARD
The lifeguard does not have an approved CPR with AED certificate. Natalie Muhs, Addison Achter, and Dave Markovitz CPR with AED certificates have expired.
Correction: Provide lifeguards who have approved CPR with AED certifications and adjust pool operation or close the pool until adequate lifeguard staffing can be provided.
Code ATCP 76.22(2)(a)3. - CPR CERTIFICATION REQUIRED
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Apr 8, 2024 Routine · 2 critical, 14 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The pressure gauge on the pump is not being maintained in operating condition.
Correction: Adjust or repair the pressure gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is no conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
STAFF TRAINED IN SAFETY DATA SHEETS
Staff are not trained in the use of the safety data sheet and where they are located.
Correction: Train staff in the use of the safety data sheet and where they are located.
Code ATCP 76.12 (4)(b)3 - STAFF TRAINED IN SAFETY DATA SHEETS
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 30.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
CERTIFIED OPERATOR REQUIRED AT WATER ATTRACTION
The water attraction (swimming pool with diving board) does not have a certified operator.
Correction: Provide a certified operator for the water attraction.
Code ATCP 76.20(2)(a)1 - CERTIFIED OPERATOR REQUIRED, WATER ATTRC
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
BIOHAZARD KIT ITEMS
The biohazard kit is present but missing items.
Correction: Replace the missing items in the biohazard kit.
Code ATCP 76.27(2)(b) - BIOHAZARD KIT ITEMS
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
SOAP-DISPENSERS OPERABLE
Soap dispenser in the girls and boys showers are not maintained in operable condition.
Correction: Maintain the soap dispenser in operable condition.
Code ATCP 76.33 (2)(e)2. - SOAP DISPENSER
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
SHEPHERD'S CROOK NON-GUARDED POOL, LONG ENOUGH
The shepherd's crook is not long enough to effect a rescue in the deepest part of pool.
Correction: Provide a shepherd's crook that is long enough to effect a rescue in deepest part of pool.
Code ATCP 76.26(1)(b)1.b. - SHEP CROOK LONG ENOUGH NON-GUARDED PO
-
Not serious
Non-critical
Source: Manitowoc County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.