Village Inn On The Lake Whirlpool

3310 MEMORIAL, Two Rivers, WI 54241 · Manitowoc County

10cited violations
5serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Manitowoc County Health Department
License / ID
BHEP-89DGKK
Status
Permitted
Phone
(920) 794-8818
Official record
Manitowoc County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025111
2024110
2023484

Inspections

  1. Oct 29, 2025 Routine · 1 critical
    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Disinfectant or sanitizer level noted at 1 PPM bromine residual; minimum is 4.0 PPM..

      Correction: Patron had been in pool prior to inspection. Chemicals were adjusted and retested at 7.6 PPM

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  2. Nov 14, 2024 Routine · 1 non-critical
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

  3. Dec 19, 2023 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. Provided DATCP Interlock Testing Form to pool operator to develop Interlock Testing Plan.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Serious Critical Repeat

      PH

      The pH is <7.0 (see comments)

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  4. Dec 14, 2023 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. Provided DATCP Interlock Testing Form to pool operator to develop Interlock Testing Plan.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Serious Critical Repeat

      PH

      The pH is <7.0 (see comments)

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  5. Dec 14, 2023 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. Provided DATCP Interlock Testing Form to pool operator to develop Interlock Testing Plan.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Serious Critical Repeat

      PH

      The pH is <7.0 (see comments)

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  6. Dec 5, 2023 Routine · 1 critical, 1 non-critical
    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. Provided DATCP Interlock Testing Form to pool operator to develop Interlock Testing Plan.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Serious Critical

      PH

      The pH is <7.0 (see comments)

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

Source: Manitowoc County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.