RecordWell Data

Tavern 10

3921 BRANCH RIVER RD, Whitelaw, WI 54247 · Manitowoc County

37cited violations
2serious tier
5inspections

Establishment

Type
Restaurant (retail food serving meals) (Retail Food - Serving Meals)
Inspected by
Manitowoc County Health Department
License / ID
JWAI-D3ZRAD
Status
Permitted
Phone
(920) 374-4675
Official record
Manitowoc County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261101
20244271

Inspections

  1. Feb 6, 2026 Routine · 1 priority, 3 priority foundation, 6 core, 1 repeat
    • Serious Priority Repeat

      PLUMBING - BACKFLOW PREVENTION - AIR GAP

      No air gap provided on food prep sink, it has an air break.

      Correction: Provide an air gap on water supply side to protect water supply.

      Code 5-202.13

    • Not serious Priority Foundation

      CLEAN-UP OF VOMITING AND DIARRHEAL EVENTS

      Food establishment does not have procedures that address responding to vomiting or diarrheal events.

      Correction: Develop procedures for responding to vomiting and diarrheal events. Specifically actions that employees must take to minimize the spread of contamination.

      Code 2-501.11

    • Not serious Priority Foundation

      CONSUMER ADVISORY - PROVIDED

      No consumer advisory provided or the consumer advisory on menu is missing hamburgers and steaks.

      Correction: Provide a consumer advisory for animal foods served in a raw or undercooked condition.

      Code 3-603.11 (A)

    • Not serious Priority Foundation

      WAREWASHING - SANITIZING SOLUTION - TESTING DEVICES

      Chlorine test strips for testing sanitizer concentrations are expired.

      Correction: Provide a test kit or other device for measuring the concentration of sanitizing solutions.

      Code 4-302.14

    • Not serious Core

      EQUIPMENT AND UTENSILS - NONFOOD CONTACT SURFACES - CONSTRUCTED

      Remove absorbent mesh from kitchen and bar shelves.

      Correction: Provide non-food contact surfaces that are constructed of a corrosion resistant, nonabsorbent, and smooth material.

      Code 4-101.19

    • Not serious Core

      THERMOMETERS - FUNCTIONALITY - EASILY READABLE

      Thermometers not provided in walkin cooler, prep table, and bar Hisense cooler.

      Correction: Provide a thermomter that is easy to read.

      Code 4-204.112 (D)

    • Not serious Core

      EQUIPMENT AND UTENSILS CONFORM TO ANSI STANDARDS

      Hisense bar cooler is not ANSI certified or approved by the department.

      Correction: Unapproved equipment shall be removed from food service.

      Code 4-205.11

    • Not serious Core

      SINGLE-USE AND SINGLE SERVICE ARTICLES - ORIGINAL CONTAINER

      Single use containers in the bar are not inverted to prevent contamination.

      Correction: Store single-use articles in their original container or use other effective means to prevent contamination.

      Code 4-903.11 (C)

    • Not serious Core

      HANDWASHING SINKS, INSTALLATION - NON-HAND OPERATED

      Handwashing sink in the bar is not non-hand operated.

      Correction: Employee handwashing sinks shall be non hand operated and if metered shall provide a flow of water without the need for reactivation for at least 15 seconds.

      Code 5-202.12 (C)

    • Not serious Core

      OPERATING WITHOUT A LICENSE - POSTING A RETAIL FOOD LICENSE

      Retail food establishment permit is not posted in a conspicous area.

      Correction: Post retail food establishment permit in a public area.

      Code ATCP 75.06 (1) (b)

  2. Nov 21, 2024 Routine · 1 priority, 1 priority foundation
    • Serious Priority

      PLUMBING - BACKFLOW PREVENTION - AIR GAP

      An air-break instead of an air gap provided on food prep sink.

      Correction: Provide an air gap on water supply side to protect water supply.

      Code 5-202.13

    • Not serious Priority Foundation

      WAREWASHING - SANITIZING SOLUTION - TESTING DEVICES

      A chlorine test kit is not available for checking sanitizer concentrations. Establishment had test strips that are for quat sanitizer.

      Correction: Provide a test kit or other device for measuring the concentration of chlorine sanitizing solutions.

      Code 4-302.14

  3. Jul 10, 2024 Pre-inspection Follow Up · 1 priority foundation, 7 core, 8 repeat
    • Not serious Priority Foundation Repeat

      PERSON IN CHARGE - EMPLOYEE ILLNESS REPORTING

      The Person in Charge (PIC) has not provided training to employees about their responsibility to inform the person in charge about any signs, symptoms and diagnosis of foodborne illness.

      Correction: The person in charge shall provide training to employees on their reponsibility to report any signs, symptoms or diagnosis of foodborne illness. Each employee must reach and sign the employee health reporting agreement and the forms must be kept on file at the facility.

      Code 2-103.11 (O)

    • Not serious Core Repeat

      CERTIFIED FOOD MANAGER - POSTING OF CERTIFICATE

      There is no approved or current food protection manager’s certificate posted in the food establishment.

      Correction: Post current food protection manager certification in conspicuous view within the food establishment.

      Code 12-201.11 (B)

    • Not serious Core Repeat

      GARBAGE/REFUSE - WASTE RECEPTACLE AT HANDWASHNG SINK

      No waste receptacle provided at handwashing sink in men's bathroom.

      Correction: Handwashing sinks using single-use paper toweling for hand drying shall be provided with a waste receptacle. Provide a waste receptacle at the handwashing sink.

      Code 5-501.16 (C)

    • Not serious Core Repeat

      SURFACE CHARACTERISTICS - INDOOR AREAS

      Bathroom stall dividers are constructed of wood (plywood and dimensional lumber with finish) and are not smooth, washable and nonabsorbent.

      Correction: The wooden stall dividers must be replaced with approved materials. Walls, floors and ceilings shall be smooth, durable and easily cleanable. If located in areas subject to moisture they shall also be non-absorbent.

      Code 6-101.11

    • Not serious Core Repeat

      FLOOR AND WALL JUNCTURES, COVED, AND ENCLOSED OR SEALED

      Floor and wall juncture in both bathrooms is not coved.

      Correction: Provide base coving.

      Code 6-201.13 (A)

    • Not serious Core Repeat

      HANDWASHING SIGNAGE

      No handwashing signage provided at bathroom handwashing sinks.

      Correction: Provide handwashing signage at all handwashing sinks used by food employees.

      Code 6-301.14

    • Not serious Core Repeat

      PUBLIC RESTROOMS - GENDER DESIGNATION

      Public restrooms are not designated with gender identification.

      Correction: Provide gender designation for mens and womens restroom.

      Code 8-201.14

    • Not serious Core Repeat

      PUBLIC RESTROOMS - WASTE RECEPTACLES

      No covered waste receptacles provided in women's restroom.

      Correction: Provide covered waste receptacles in each stall in women's restroom.

      Code 8-201.15

  4. Jul 10, 2024 Pre-inspection Follow Up · 1 priority foundation, 7 core, 8 repeat
    • Not serious Priority Foundation Repeat

      PERSON IN CHARGE - EMPLOYEE ILLNESS REPORTING

      The Person in Charge (PIC) has not provided training to employees about their responsibility to inform the person in charge about any signs, symptoms and diagnosis of foodborne illness.

      Correction: The person in charge shall provide training to employees on their reponsibility to report any signs, symptoms or diagnosis of foodborne illness. Each employee must reach and sign the employee health reporting agreement and the forms must be kept on file at the facility.

      Code 2-103.11 (O)

    • Not serious Core Repeat

      CERTIFIED FOOD MANAGER - POSTING OF CERTIFICATE

      There is no approved or current food protection manager’s certificate posted in the food establishment.

      Correction: Post current food protection manager certification in conspicuous view within the food establishment.

      Code 12-201.11 (B)

    • Not serious Core Repeat

      GARBAGE/REFUSE - WASTE RECEPTACLE AT HANDWASHNG SINK

      No waste receptacle provided at handwashing sink in men's bathroom.

      Correction: Handwashing sinks using single-use paper toweling for hand drying shall be provided with a waste receptacle. Provide a waste receptacle at the handwashing sink.

      Code 5-501.16 (C)

    • Not serious Core Repeat

      SURFACE CHARACTERISTICS - INDOOR AREAS

      Bathroom stall dividers are constructed of wood (plywood and dimensional lumber with finish) and are not smooth, washable and nonabsorbent.

      Correction: The wooden stall dividers must be replaced with approved materials. Walls, floors and ceilings shall be smooth, durable and easily cleanable. If located in areas subject to moisture they shall also be non-absorbent.

      Code 6-101.11

    • Not serious Core Repeat

      FLOOR AND WALL JUNCTURES, COVED, AND ENCLOSED OR SEALED

      Floor and wall juncture in both bathrooms is not coved.

      Correction: Provide base coving.

      Code 6-201.13 (A)

    • Not serious Core Repeat

      HANDWASHING SIGNAGE

      No handwashing signage provided at bathroom handwashing sinks.

      Correction: Provide handwashing signage at all handwashing sinks used by food employees.

      Code 6-301.14

    • Not serious Core Repeat

      PUBLIC RESTROOMS - GENDER DESIGNATION

      Public restrooms are not designated with gender identification.

      Correction: Provide gender designation for mens and womens restroom.

      Code 8-201.14

    • Not serious Core Repeat

      PUBLIC RESTROOMS - WASTE RECEPTACLES

      No covered waste receptacles provided in women's restroom.

      Correction: Provide covered waste receptacles in each stall in women's restroom.

      Code 8-201.15

  5. Apr 4, 2024 Pre-inspection · 1 priority foundation, 8 core
    • Not serious Priority Foundation

      PERSON IN CHARGE - EMPLOYEE ILLNESS REPORTING

      The Person in Charge (PIC) has not provided training to employees about their responsibility to inform the person in charge about any signs, symptoms and diagnosis of foodborne illness.

      Correction: The person in charge shall provide training to employees on their reponsibility to report any signs, symptoms or diagnosis of foodborne illness. Each employee must reach and sign the employee health reporting agreement and the forms must be kept on file at the facility.

      Code 2-103.11 (O)

    • Not serious Core

      CERTIFIED FOOD MANAGER – REQUIREMENT - FOOD ESTABLISHMENTS

      There is no approved or current certified food manager for this establishment.

      Correction: Provide an approved certified food protection manager in the food establishment within 90 DAYS.

      Code 12-201.11 (A) (1)

    • Not serious Core

      CERTIFIED FOOD MANAGER - POSTING OF CERTIFICATE

      There is no approved or current food protection manager’s certificate posted in the food establishment.

      Correction: Post current food protection manager certification in conspicuous view within the food establishment.

      Code 12-201.11 (B)

    • Not serious Core

      GARBAGE/REFUSE - WASTE RECEPTACLE AT HANDWASHNG SINK

      No waste receptacle provided at handwashing sink in men's bathroom.

      Correction: Handwashing sinks using single-use paper toweling for hand drying shall be provided with a waste receptacle. Provide a waste receptacle at the handwashing sink.

      Code 5-501.16 (C)

    • Not serious Core

      SURFACE CHARACTERISTICS - INDOOR AREAS

      Bathroom stall dividers are constructed of wood (plywood and dimensional lumber with finish) and are not smooth, washable and nonabsorbent.

      Correction: The wooden stall dividers must be replaced with approved materials. Walls, floors and ceilings shall be smooth, durable and easily cleanable. If located in areas subject to moisture they shall also be non-absorbent.

      Code 6-101.11

    • Not serious Core

      FLOOR AND WALL JUNCTURES, COVED, AND ENCLOSED OR SEALED

      Floor and wall juncture in both bathrooms is not coved.

      Correction: Provide base coving.

      Code 6-201.13 (A)

    • Not serious Core

      HANDWASHING SIGNAGE

      No handwashing signage provided at bathroom handwashing sinks.

      Correction: Provide handwashing signage at all handwashing sinks used by food employees.

      Code 6-301.14

    • Not serious Core

      PUBLIC RESTROOMS - GENDER DESIGNATION

      Public restrooms are not designated with gender identification.

      Correction: Provide gender designation for mens and womens restroom.

      Code 8-201.14

    • Not serious Core

      PUBLIC RESTROOMS - WASTE RECEPTACLES

      No covered waste receptacles provided in women's restroom.

      Correction: Provide covered waste receptacles in each stall in women's restroom.

      Code 8-201.15

Source: Manitowoc County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.