Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Manitowoc County Health Department
License / ID
SCHE-DD4S4P
Status
Permitted
Phone
(920) 755-4000
Official record
Manitowoc County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261134
20251205

Inspections

  1. Apr 7, 2026 Routine · 4 critical, 9 non-critical, 5 repeat
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      RESPONSIBLE SUPERVISOR INTERLOCK TESTING

      Responsible supervisor is not ensuring that monthly interlock testing is done.

      Correction: Have the responsible supervisor ensure that monthly interlock tests are done.

      Code ATCP 76.21 (1)(c)5.- INTERLOCK TESTING

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      1 emergency blanket is missing in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present. On the signage it states supervision is only needed for the whirlpool.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck is cracking and pitting.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical Repeat

      POOL FENCE- 5 FEET HIGH

      The outdoor patio needs to have an approved fence installed at least 5 feet high. The installation of the garage doors was not previously approved to enclose the patio.

      Correction: Install a fence that is at least 5 feet high.

      Code ATCP 76.34(3)(a) - FENCE HEIGHT

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Repeat

      Modification(s) made but no DSPS Approval available for them.

      The operator modified a pool and did not submit pool construction plans to DSPS for review and approval.

      Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.

      Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A

    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical Corrected on site

      PH

      The pH is 6.8

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Corrected on site

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

  2. Apr 30, 2025 Pre-inspection · 5 critical, 15 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      The license is not posted for public view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weir doors missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      LABEL, CONSPICUOUS

      Chemical container is not conspicuously labeled (acid tank).

      Correction: Provide a conspicuous, easily visible and read label on the chemical container.

      Code ATCP 76.12 (1)(a)

    • Not serious Non-critical

      CHEMICALS STORED IN ORIGINAL CONTAINER

      Acid is not stored in original or properly labeled container.

      Correction: Store chemicals in original or properly labeled containers.

      Code ATCP 76.12 (2)(a) - CHEMICALS STORED ORIGINALCONTAINER

    • Not serious Non-critical

      SAFETY DATA SHEET BACKUP

      A backup copy of the safety data sheets was not available.

      Correction: Maintain a backup copy of safety data sheets for each chemical on site.

      Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY

    • Not serious Non-critical

      STAFF TRAINED IN SAFETY DATA SHEETS

      Staff are not trained in the use of the safety data sheet and where they are located.

      Correction: Train staff in the use of the safety data sheet and where they are located.

      Code ATCP 76.12 (4)(b)3 - STAFF TRAINED IN SAFETY DATA SHEETS

    • Not serious Non-critical

      LABEL, STORE, MIX CHEMICALS, LOCAL, STATE AND FEDERAL COMPLIANCE

      Labeling of chemicals is not in compliance with applicable local, state, and federal regulations.

      Correction: Comply with applicable local, state, and federal regulations.

      Code ATCP 76.12 - CHEMICALS COMPLIANCE WITH OTHER STATE, FEDERAL,

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical

      FIRST AID KIT -RESUSCITATION POCKET MASK

      The first aid kit is missing a resuscitation pocket mask.

      Correction: Provide a resuscitation pocket mask for the first aid kit.

      Code ATCP 76.27(1)(b)8.- RESUSCITATION MASK

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE-NO DIVING

      No-Diving signage is not present where it is required.

      Correction: Post signage indicating No-Diving.

      Code ATCP 76.29(1)(d) - NO DIVING

    • Not serious Non-critical

      WHIRLPOOLS-RULES, MINORS UNDER AGE 6

      Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.

      Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.

      Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      POOL FENCE- 5 FEET HIGH

      The outdoor patio needs to have an approved fence installed at least 5 feet high. The installation of the garage doors was not previously approved to enclose the patio.

      Correction: Install a fence that is at least 5 feet high.

      Code ATCP 76.34(3)(a) - FENCE HEIGHT

    • Serious Critical

      Modification(s) made but no DSPS Approval available for them.

      The operator modified a pool and did not submit pool construction plans to DSPS for review and approval. Two large glass garage doors have been added to the pool which the operator intends to open while the pool is in operation. This is a significant alteration and must be plan reviewed by DSPS. The women's bathroom was converted into a guest room/apartment and women are being redirected thru the exercise center into those locker rooms. The floor that leads to the bathrooms and the locker room is carpeted which is not allowed under SPS 390. The removal of the original women's bathroom and the installation of carpet also requires plan approval/review by DSPS for compliance with SPS 390.

      Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool. A conditional license has been issued regarding these issues. Failure to submit plans to DSPS within 90 days and make any required repairs will result in license suspension. The overhead doors on the extrerior wall must remain locked at all ti

      Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      The drinking fountain is not operational].

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

    • Serious Critical

      POOL AREA ENCLOSED

      The outside pool area is not enclosed with a fence or other approved barrier. Overhead garage doors were installed without DSPS approval that lead onto an unfenced patio.

      Correction: Close the pool and restrict access to the pool area until a proper enclosure has been installed with self-closing, latching and lockable gates or doors.

      Code ATCP 76.34(4)(a)(1m) - POOL AREAS ENCLOSED

    • Serious Critical

      GATES AND DOORS-SELF-CLOSING

      The gate or door does not self-close. The newly installed man door is not self-closing.

      Correction: Provide a self-closing gate or door.

      Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

Source: Manitowoc County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.