RecordWell Data

Holiday Inn Express

4210 BARBICAN AV, Weston, WI 54476 · Marathon County

20cited violations
2serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Marathon County Health Department
License / ID
SBRN-AS7PBB
Status
Permitted
Phone
(715) 359-1280
Official record
Marathon County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026281
2025130
2024191

Inspections

  1. Sep 14, 2026 Routine · 1 critical, 5 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN ACTION LEVEL

      The combined chlorine plan does not include the combined chlorine action level.

      Correction: Includes the combined chlorine action level in the combined chlorine plan.

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical

      COMBINED CHLORINE PLAN VOLUME OF SOURCE WATER ADDED-RANGE

      The combined chlorine plan does not include range of volume of fresh source water added to pool each day.

      Correction: Include the range of volume of fresh source water added to pool each day in the combined chlorine plan.

      Code ATCP 76.14(5)(e)2.c. - VOLUME OF SOURCE WATER ADDED

    • Not serious Non-critical

      COMBINED CHLORINE PLAN SHOWERING REQUIREMENTS

      The combined chlorine plan does not include description of showering requirements and how communicated to patrons.

      Correction: Include a description of showering requirements and how communicated to patrons in the combined chlorine plan.

      Code ATCP 76.14(5)(e)2.d. - SHOWERING REQUIREMENTS

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 625 mV.

      Correction: Maintain water potential between 650−900 mV

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit thiosulfate reagent has not been replaced as recommended by the manufacturer. Expired 1/26.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Serious Critical

      INTERLOCK LOG-INFORMATION

      The monthly testing log is incomplete. Log must include persons name, results and space for corrective actions.

      Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.

      Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED

  2. Jan 14, 2026 Routine · 2 non-critical
    • Not serious Non-critical

      SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED

      Women's bathroom shower mat is falling apart.

      Correction: Replace shower mat in women's bathroom.

      Code ATCP 76.33 (2)(a)1. - GOOD REPAIR

    • Not serious Non-critical

      POOL DECK-INDOOR-DISINFECTED

      Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions. Currently being disinfected monthly.

      Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.

      Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED

  3. Jan 14, 2025 Routine · 3 non-critical, 1 repeat
    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      POOL RULES LETTER OR SYMBOL SIZE

      Pool rules letters are <1 inch in height..

      Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.

      Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

  4. Feb 8, 2024 Routine · 1 critical, 8 non-critical
    • Not serious Non-critical

      DOORS

      Doors to chemical storage areas not marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      FIRST AID KIT-INSTANT COLD PACKS

      The first aid kit is missing instant cold packs.

      Correction: Provide instant cold packs for the first aid kit.

      Code ATCP 76.27(1)(b)9. - INSTANT COLD PACKS

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      POOL BASIN MAINTAINED CLEAN AND SANITARY

      Tiles along the wading pools water/air interface have accumulated a film.

      Correction: Maintained the pool basin in a clean and sanitary condition.

      Code ATCP 76.33(1)(a)3 - POOL BASIN NOT CLEAN AND SANITARY

    • Not serious Non-critical

      POOL DECK-RINSED AS NEEDED

      Pool deck area not rinsed as needed to prevent microbial growth. Algae growth is present at the base of the stairs to the frog slide.

      Correction: Rinse pool deck area as needed to prevent microbial growth.

      Code ATCP 76.33(1)(b)1.b. - DECK RINSED

    • Serious Critical

      TELEPHONE ACCESSIBLE

      The telephone rings directly to front desk.

      Correction: New code requires a phone that can directly dial or ring to 911.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

Source: Marathon County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.