Woodson YMCA Aspirus
3402 HOWLAND AV, Weston, WI 54476 · Marathon County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Marathon County Health Department
- License / ID
- HSAT-7QXRHW
- Status
- Permitted
- Phone
- (715) 841-1850
- Official record
- Marathon County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 2 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 6 | 1 |
| 2023 | 1 | 3 | 0 |
Inspections
-
Jan 26, 2026 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
Valves above the water heater, and by the 8" pipe coming from the sand filters, are not tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
8" pipe coming from the sand filters is not marked to indicate water direction.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
FILTER MEDIA INSPECTED ANNUALLY
Filter media is not being inspected annually or cleaned or replaced as necessary.
Correction: Inspect the filters annually and clean and replace media as needed.
Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY
-
Not serious
Non-critical
RESCUE EQUIPMENT ACCESSIBLE
Wheeled white boards used for instruction were blocking access to the shepherds crook.
Correction: Maintain rescue equipment in a conspicuous and accessible location.
Code ATCP 76.26(1)(a)2. - RESCUE EQPT ACCESSIBLE
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Tiles by the west guard station, to the left of the 5ft depth marker, are broken.
Correction: Maintain pool deck area in good repair. Repair or replace tile.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
The CO alarm in the equipment room was not functional.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
Corrected on site
CO ALARM-POOL AREA
The CO alarm in the pool area was not operational.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
-
Feb 13, 2025 Routine · No items found
No violations cited.
-
Apr 11, 2024 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
Corrected on site
DOORS
Mark the mechanical/pump room door to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Taylor test kit reagents have exceeded the expiration dates listed on the reagent bottle.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
Hand railings are loose.
Correction: Secure the hand railings so they are tightly fastened to the pool deck and basin.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
Corrected on site
-
May 3, 2023 Routine · 3 non-critical
-
Not serious
Non-critical
LIFEGUARD AND ATTENDANT STAFFING PLAN
The lifeguard staffing plan does not identify each first aid station.
Correction: Edit the written plan pursuant to the requirements of ATCP 76.22 and resubmit it for approval.
Code [A] ATCP 76.22(1)(a)
-
Not serious
Non-critical
SELF-CLOSING AND LATCHING GATES
The double doors toward the shallow end of the pool bind and do not self-latch.
Correction: Repair the door immediately so that it is self-closing and latching.
Code [A] ATCP 76.34(4)
-
Not serious
Non-critical
CRACKS OR PITTING IN THE POOL BASIN
Small square tiles between dive platforms 5 and 6 are cracked and relatively sharp.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code [B] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Source: Marathon County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.