Inspections
-
Mar 30, 2026 Routine · 3 critical, 6 non-critical, 1 repeat
-
Not serious
Non-critical
HIGH RATE SAND FILTER BACKWASHING
Sand filter is not being backwashed according to manufacturers instructions and not based upon the pressure reading.
Correction: Sand filters should be backwashed according to the differential in pressure from the last backwashed performed.
Code ATCP 76.11(6)(b) 2. - HIGH RATE SAND FILTER BACKWASH
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
RESPONSIBLE SUPERVISOR INTERLOCK TESTING
Responsible supervisor is not ensuring that monthly interlock testing is done.
Correction: Have the responsible supervisor ensure that monthly interlock tests are done.
Code ATCP 76.21 (1)(c)5.- INTERLOCK TESTING
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pipe connection to the heat source is leaking
Correction: Maintain the pool equipment.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
OPERATOR KNOWLEDGE- ELECTRICAL INTERLOCK FUNCTION
The person responsible is not able to describe how the chemical feeder electrical interlock functions.
Correction: Ensure that operator can describe how the chemical feeder electrical interlock functions.
Code ATCP 76.13 (1)(c)2.b - HOW ELECTRICAL INTERLOCK FUNCTIONS
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible does not have knowledge of the interlock process.
Correction: Ensure that operator can describe how monthly testing is performed and how the interlock works.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock since last year.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Not serious
Non-critical
-
Mar 26, 2025 Routine · 8 non-critical, 3 repeat
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The float is stuck on the flowmeter
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
READABLE CHART
Labels, tags or color-coding does not correspond to a conspicuously posted, easily read chart that explains the system.
Correction: Provide the chart for labels, tags and color-coding
Code ATCP 76.11(5m)(b) - PIPING CHART
-
Not serious
Non-critical
Repeat
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
FIRST AID KIT-EYE WASH SOLUTION
The first aid kit eye wash solution expired.
Correction: Provide new eye wash solution for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Not serious
Non-critical
WHIRLPOOLS-SIGNAGE POSTED
Whirlpool rules do not contain the word Warning above them.
Correction: Correct signage for whirlpool to include the word WARNING.
Code ATCP 76.29(3) - WHIRLPOOL RULES POSTED
-
Not serious
Non-critical
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The shower fixture is leaking.
Correction: Maintain the shower in good repair.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin is missing two tiles in the basin.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
-
Apr 4, 2024 Routine · 2 critical, 10 non-critical
-
Not serious
Non-critical
READABLE CHART
Labels, tags or color-coding does not correspond to a conspicuously posted, easily read chart that explains the system.
Correction: Provide the chart for labels, tags and color-coding
Code ATCP 76.11(5m)(b) - PIPING CHART
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is no conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
LABEL, EROSION FEEDER
The erosion feeder does not have a label that lists the chemical name.
Correction: Provide the chemical name on the erosion feeder label.
Code ATCP 76.12 (1)(b) - EROSION FEEDER
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
INTERLOCKED-ELECTRICAL
Power to recirculation system is not interlocked with the power to the chemical feed.
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
EMERGENCY BLANKETS
Only one emergency blanket is available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed and the daily pressure and flowmeter readings..
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin is missing a blue tile on the stairs.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
No documentation on when equalizers wer last replaced.
Correction: Provide documentation that the equalizer cover has been replaced in the past five years or replace with new cover and document.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not present. Must dial 0 for front desk.
Correction: Provide a working telephone or other technology capable of connecting with emergency services and post corrected directions for usage of emergency telephone.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
Source: Marathon County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.