RecordWell Data

Vacay Dubay

202895 DUBAY DR, Mosinee, WI 54455 · Marathon County

12cited violations
2serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Marathon County Health Department
License / ID
MSCH-CKRSRU
Status
Permitted
Phone
(608) 225-8675
Official record
Marathon County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026162
2025100
2024130
2023130

Inspections

  1. May 26, 2026 Routine · 6 non-critical
    • Serious Critical

      Slip-resistant flooring in shower and bathtubs

      The bathtub on the main floor is not provided with slip-resistant flooring or materials.

      Correction: Slip-resistant flooring or materials shall be provided in all shower and bathtub basins.

      Code ATCP 72.17(5)(f)

    • Serious Critical

      Prohibited food items offered

      Unapproved food items were located upon the inspection including: bulk oats, pancake mix, bulk coffee cans, bulk spices, sauce, butter, beer, etc.

      Correction: Discontinue providing the prohibited food item.

      Code ATCP 72.21(1)(b)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The lower master bedroom does not have a working smoke alarm. The two upstairs bedrooms do not have smoke alarms in them.

      Correction: Provide a working smoke alarm within each sleeping room and send images to your inspector, once installed. These need to be installed before any new tenants arrive.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Priority Foundation

      TCS foods, opened non-TCS foods, ice - removal at guest turnover

      TCS foods and opened non-TCS food items including ice are not discarded between guest stays. This include disgarding any sauces in the fridge, beer, butter, bulk spices and cooking ingredients, bulk coffee, etc.

      Correction: Discard all TCS foods and opened non-TCS food items including ice at guest turnover and switch to providing pre-packaged single-use items that are shelf-stable. Individually packaged coffee grounds, tea bags, hot chocolate, pre-packaged crackers and cookies, and salt and pepper are all allowed.

      Code ATCP 72.21(3)

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

  2. Jan 8, 2025 Routine · No items found

    No violations cited.

  3. Jan 25, 2024 Follow Up · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      DESIGN-CONSTRUCTION, MATERIALS, EASILY CLEANABLE, DURABLE

      The side railing for the upper bunk bed does not meet the required 6" height above the mattress (it measured at about 4").

      Correction: 2 options: 1. Separate the bunk beds, creating two side by side twin beds 2. Add additional railing segments to increase the height above the mattress to 6 " on all sides.

      Code ATCP 72.11 (1)

    • Not serious Non-critical Repeat

      SMOKE DETECTORS - REQUIREMENT

      Smoke detector was not in working order in the hallway by the kitchen (battery was missing).

      Correction: Provide operational smoke detectors in all sleeping rooms and required locations. Once the smoke detector is back in working order please send me a video showing the testing and proper operation of the smoke detector. The facility is not to be rented until the smoke detector is back in proper working order.

      Code ATCP 72.14 (2) (c)

    • Not serious Non-critical Repeat

      GENERAL MAINTENANCE

      The vertical guard spacing is measured at 8". These guards extend from the basement to the second floor.

      Correction: The vertical guards must be adjusted so that the max. spacing is 6", 4" preferrably. The property should not be rented until the vertical guard spacing is adjusted to appropriate dimensions.

      Code [C] ATCP 72.15 (1)

  4. Nov 15, 2023 Routine · 3 non-critical
    • Not serious Non-critical

      DESIGN-CONSTRUCTION, MATERIALS, EASILY CLEANABLE, DURABLE

      The side railing for the upper bunk bed does not meet the required 6" height above the mattress (it measured at about 4").

      Correction: 2 options: 1. Separate the bunk beds, creating two side by side twin beds 2. Add additional railing segments to increase the height above the mattress to 6 " on all sides.

      Code ATCP 72.11 (1)

    • Not serious Non-critical

      SMOKE DETECTORS - REQUIREMENT

      Smoke detector was not in working order in the hallway by the kitchen (battery was missing).

      Correction: Provide operational smoke detectors in all sleeping rooms and required locations. Once the smoke detector is back in working order please send me a video showing the testing and proper operation of the smoke detector. The facility is not to be rented until the smoke detector is back in proper working order.

      Code ATCP 72.14 (2) (c)

    • Not serious Non-critical

      GENERAL MAINTENANCE

      The vertical guard spacing is measured at 8". These guards extend from the basement to the second floor.

      Correction: The vertical guards must be adjusted so that the max. spacing is 6", 4" preferrably. The property should not be rented until the vertical guard spacing is adjusted to appropriate dimensions.

      Code [C] ATCP 72.15 (1)

Source: Marathon County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.