Comfort Inn

5810 SCHOFIELD AV, Weston, WI 54476 · Marathon County

68cited violations
9serious tier
9inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Marathon County Health Department
License / ID
SBRN-CNDQGV
Status
Permitted
Phone
(989) 444-0333 ext. Bharit, owner
Official record
Marathon County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20254343
20244346
2023100

Inspections

  1. Dec 10, 2025 Follow Up · 9 non-critical, 9 repeat
    • Not serious Non-critical Repeat

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is 50/50.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer prior to re-opening.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical Repeat

      FILTERS MAINTAINED OPERABLE

      Top of filter has a substatial leak.

      Correction: Maintain filter shells and appurtenances in operable condition.

      Code ATCP 76.11(6)(a) 2. - FILTER OPERABLE

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN ACTION LEVEL

      The combined chlorine plan does not include the combined chlorine action level.

      Correction: Includes the combined chlorine action level in the combined chlorine plan along with cleaning and disinfection schedule and product used..

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Alkalinity and some of the chlorine test reagents have expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in a whirlpool and pool water is not tested at daily for the combined chlorine level.

      Correction: Test pool water daily in the whirlpool for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical Repeat

      FIRST AID KIT-ADHESIVE TAPE

      The first aid kit is missing adhesive tape.

      Correction: Provide adhesive tape for the first aid kit.

      Code ATCP 76.27(1)(b)4. - ADHESIVE TAPE

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical Repeat

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The duct vent cover in the pool enclosure is in need of cleaning

      Correction: Clean vent cover on air handle duct.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical Repeat

      AIR MOVEMENT

      Ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. Two large dehumidifiers are present in the pool enclosure. The outside air temp is 30-40 F and condisation is accumulating on the doors, windows, and along the floor to wall juncture on the west side of the enclosure.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

  2. Nov 18, 2025 Routine · 10 non-critical, 1 repeat
    • Not serious Non-critical

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is 50/50.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer prior to re-opening.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      FILTERS MAINTAINED OPERABLE

      Top of filter has a substatial leak.

      Correction: Maintain filter shells and appurtenances in operable condition.

      Code ATCP 76.11(6)(a) 2. - FILTER OPERABLE

    • Not serious Non-critical

      COMBINED CHLORINE PLAN ACTION LEVEL

      The combined chlorine plan does not include the combined chlorine action level.

      Correction: Includes the combined chlorine action level in the combined chlorine plan along with cleaning and disinfection schedule and product used..

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Alkalinity and some of the chlorine test reagents have expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in a whirlpool and pool water is not tested at daily for the combined chlorine level.

      Correction: Test pool water daily in the whirlpool for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical

      FIRST AID KIT-ADHESIVE TAPE

      The first aid kit is missing adhesive tape.

      Correction: Provide adhesive tape for the first aid kit.

      Code ATCP 76.27(1)(b)4. - ADHESIVE TAPE

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The duct vent cover in the pool enclosure is in need of cleaning

      Correction: Clean vent cover on air handle duct.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical

      AIR MOVEMENT

      Ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. Two large dehumidifiers are present in the pool enclosure. The outside air temp is 30-40 F and condisation is accumulating on the doors, windows, and along the floor to wall juncture on the west side of the enclosure.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      No documentation is present and is not documented that the equalizer covers have been replaced.

      Correction: Maintain a log that can be used to evaluate the equalizer covers. They do not need to be replaced like for like as the main drain grates. The license is changed to conditional until proof of replacement has been provided. If proper documentation is not provided within 30 days the pool will be closed until documentation is provide and the license may be voided.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  3. Feb 19, 2025 Re-inspection · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      WHIRLPOOLS-RULES, HEALTH CONDITIONS

      Signage for whirlpool is not worded correctly: Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool.

      Correction: Include correct language for rule stating: Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool.

      Code ATCP 76.29(3)(a) - HEALTH CONDITIONS

    • Not serious Non-critical Repeat

      POOL DECK-DEPTH MARKINGS MAINTAINED

      No depth markings are present in the interior of the whirlpool.

      Correction: Install depth markings along the interior edge of the whirlpool.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

    • Not serious Non-critical Repeat

      POOL EQUIPMENT-PROPERLY MAINTAINED

      One of the sand filters are leaking.

      Correction: Repair sand filter leak.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

  4. Jan 16, 2025 Routine · 3 critical, 9 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical Repeat

      WHIRLPOOLS-RULES, HEALTH CONDITIONS

      Signage for whirlpool is not worded correctly: Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool.

      Correction: Include correct language for rule stating: Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool.

      Code ATCP 76.29(3)(a) - HEALTH CONDITIONS

    • Not serious Non-critical

      POOL DECK-DEPTH MARKINGS MAINTAINED

      No depth markings are present in the interior of the whirlpool.

      Correction: Install depth markings along the interior edge of the whirlpool.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

    • Not serious Non-critical

      WALLS, CEILINGS, FLOORS

      The walls, ceilings and floors in a pool area have not been maintained in clean and sanitary condition. The ceiling is leaking, dripping into the pool with eiling tiles saturated with water. The floor has accumulation of debris especially along walls, a windowsill has algae growth present and north wall has significant amount of mildew growth which is spreading onto the no lifeguard sign.

      Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition.

      Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      One of the sand filters are leaking.

      Correction: Repair sand filter leak.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical

      SPECTATOR AREAS CLEAN

      The spectator area tables are soiled.

      Correction: Maintain the spectator area in clean condition.

      Code ATCP 76.33(1)(f)1. - SPECTATOR AREA CLEAN

    • Not serious Non-critical

      DRINKING FOUNTAIN MAINTAINED

      The drinking fountain is not clean.

      Correction: Maintain the drinking fountain in clean and sanitary condition.

      Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 3.0 ppm chlorine for whirlpools, disinfectant level measured at 2.4 ppm chlorine[ ] for [list disinfectant].

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      RESPONSIBLE SUPERVISOR MAINTAIN ORDER

      No monthly pool log was available to verify that the pool tests were completed todya with the disinfectant level being below the minimum. In addition with the number of violations present and overall cleanliness of the pool enclosure there appears to be a lack of managerial contol for the pools and the enclosure.

      Correction: Ensure that daily maintenance is occuring and cleaning is occuring.

      Code ATCP 76.21 (1)(c)1. - MAINTAIN ORDER

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is located just outside the door within 25 feet of enclosure with no signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

  5. Aug 20, 2024 Routine · 5 non-critical, 1 repeat
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      WHIRLPOOLS-RULES, HEALTH CONDITIONS

      Signage for whirlpool has incorrect wording for this rule: Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool. No mention of elderly personon required

      Correction: Change signage to adjust rule stating: Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool. I would contact signage company that sold you the sign without the updated language ode was effective 9/24/23.

      Code ATCP 76.29(3)(a) - HEALTH CONDITIONS

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical

      OPERATING REPORTS-WATER TEMPERATURE

      The operator did not record the following on the operating report: Daily water temperature.

      Correction: Record the following on the operating report: Daily water temperature.

      Code ATCP 76.32(1)(f) - WATER TEMP

  6. Apr 18, 2024 Follow Up · 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      No combined chlorine plan. Working on it incomplete at this time.

      Correction: Develope a written combined chlorine plan.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POOL DECK-DEPTH MARKINGS MAINTAINED

      Depth markings along the inside edge of the pool are missing.

      Correction: Depth marking are required on the interior of the whirlpool basin similar to how the pool depth marking are present.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

  7. Mar 15, 2024 Re-inspection · 3 critical, 12 non-critical, 8 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Repair or replace flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      FILTER MEDIA INSPECTED ANNUALLY

      Filter media is not being inspected annually or cleaned or replaced as necessary.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical Repeat

      DOORS

      Doors to chemical storage areas not marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical Repeat Corrected on site

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      THERMOMETER RETURN LINE

      An accurate thermometer is not located in the pool water return line. Currently was reading 112 F with whirlpool actually at 103.5 F.

      Correction: Provide an accurate thermometer in the pool water return line.

      Code ATCP 76.19(4)(a)1 - THERMOMETER

    • Not serious Non-critical

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      This pool basin is now required to have a certified pool operator within 90 days.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Not serious Non-critical Repeat

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical

      WHIRLPOOLS-SIGNAGE POSTED

      Whirlpool rules are not posted in the whirlpool area.

      Correction: Post the rule for the whirlpool.

      Code ATCP 76.29(3) - WHIRLPOOL RULES POSTED

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      There is a leak in the recirculation pump.

      Correction: Maintain the pool equipment.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      No combined chlorine plan.

      Correction: Develope a written combined chlorine plan.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical Repeat

      POOL DECK-DEPTH MARKINGS MAINTAINED

      Depth markings along the inside edge of the pool are faded.

      Correction: Maintain pool deck area so that depth markings along the edge of the pool are clearly visible and readable.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

    • Serious Critical Repeat

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Chlorine is not stored separately from acid.

      Correction: Store oxidizers separately from acids as much as possible.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Repeat

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  8. Jan 25, 2024 Routine · 3 critical, 9 non-critical
    • Not serious Non-critical

      DOORS

      Doors to chemical storage areas not marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      No combined chlorine plan.

      Correction: Develope a written combined chlorine plan.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is <650 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      TEST KIT APPROVED

      Chlorine testing was being performed with an unapproved test kit.

      Correction: Obtain an approved test kit for chemical testing.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      ELECTRONIC MONITORING MAINTENANCE

      The electronic monitoring device is not proper functioning .

      Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate.

      Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED

    • Not serious Non-critical

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      POOL DECK-DEPTH MARKINGS MAINTAINED

      Depth markings along the inside edge of the pool are faded.

      Correction: Maintain pool deck area so that depth markings along the edge of the pool are clearly visible and readable.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

    • Serious Critical

      Modification(s) made but no DSPS Approval available for them.

      The operator modified a pool, engineer completed compliance statement but no documentation that compliance was completed by DSPS as required..

      Correction: Verify that DSPS compliance inspection was perfromed and provide documentation.

      Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A

    • Serious Critical

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Chlorine is not stored separately from acid.

      Correction: Store oxidizers separately from acids as much as possible.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

  9. Aug 24, 2023 Routine · No items found

    No violations cited.

Source: Marathon County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.