RecordWell Data

The Villas At Foxwood

4401 W DEER RUN DR, Brown Deer, WI 53223 · Milwaukee County

14cited violations
7serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
North Shore Health Department
License / ID
BSIY-DJDSSN
Status
Permitted
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026132
20253115

Inspections

  1. Jun 1, 2026 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Several reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Serious Critical

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  2. Sep 2, 2025 Re-inspection · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Repeat

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. 7/22/25 - Emergency intercom system has been installed in pool area. It was tested and connects to a 3rd party dispatch service. This type of system requires a variance.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services. Facility shall submit a variance application and supporting documentation for the emergency intercom system.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  3. Jul 22, 2025 Pre-inspection Follow Up · 1 critical, 1 non-critical
    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. 7/22/25 - Emergency intercom system has been installed in pool area. It was tested and connects to a 3rd party dispatch service. This type of system requires a variance.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services. Facility shall submit a variance application and supporting documentation for the emergency intercom system.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  4. Jul 2, 2025 Pre-inspection · 3 critical, 4 non-critical
    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Skimmers, gutters, drains not maintained clean. Interior surfaces of skimmers are coated with a slippery film.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 40 ppm.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical Corrected on site

      RESCUE EQUIPMENT ACCESSIBLE

      The rescue equipment is not in a conspicuous place and readily accessible. Components of shepherd's crook were not assembled at start of the inspection - hook portion of crook was in one area of the pool deck, and the pole was in another area. Rope is tangled on the ring buoy.

      Correction: Maintain rescue equipment in a conspicuous and accessible location. Shepherd's crook was assembled during the inspection and placed in a readily accessible location. Untangle ring buoy rope.

      Code ATCP 76.26(1)(a)2. - RESCUE EQPT ACCESSIBLE

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.0 for bromine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Bromine must be in the range of 3.0 ppm to 10 ppm for effective disinfection.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      GATES AND DOORS-LATCHING

      The gate or door does not latch. Front entry gate to pool does not latch when it closes.

      Correction: Provide a latching door.

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

Source: North Shore Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.