Holiday Inn Milwaukee Riverfront
4700 N PORT WASHINGTON RD, Glendale, WI 53212 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- North Shore Health Department
- License / ID
- RGON-9KKM76
- Status
- Permitted
- Phone
- (414) 962-6040
- Official record
- North Shore Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 4 | 0 |
| 2024 | 3 | 22 | 1 |
Inspections
-
Apr 23, 2025 Re-inspection · No items found
No violations cited.
-
Apr 16, 2025 Routine · 4 non-critical, 1 repeat
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate is 7.2 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Corrected on site
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a pool is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level. Educational moment.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Corrected on site
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity. Educational moment.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
Repeat
WATER LEVEL-SKIMMERS MAINTAINED
Water level in a skimmer pool is not allowing for effective skimming. The water level is too high.
Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.
Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED
-
Not serious
Non-critical
-
Apr 19, 2024 Re-inspection · 5 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir door missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The ORP is connected but turned off. Also the ORP reader does not match our manual test.
Correction: Maintain the pool equipment. Repair and adjust ORP reader.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
AIR MOVEMENT
Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. There is significant condensation build up on the ceiling and the windows. This is an indication the facility does not have proper ventilation.
Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.
Code ATCP 76.33(4)(b) - AIR MOVEMENT
-
Not serious
Non-critical
Repeat
-
Apr 1, 2024 Re-inspection · 8 non-critical, 8 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir door missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
WATER LEVEL-SKIMMERS MAINTAINED
Water level in a skimmer pool is not allowing for effective skimming. The water level is too high.
Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.
Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing for combined chlorine and alkalinity.
Correction: Record the following on the operating report, results for chemical testing for combined chlorine and alkalinity.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
Repeat
POOL DECK-INDOOR-DISINFECTED
Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions. The pool deck is dirty and has pooling water around the pool. The water is not effectively draining. At the time of the inspection, the pool was filled too high and spilling on to the deck. The person in charge indicated that the pool loses 8 inches of water each day and needs to be refilled. Sometimes the pool is over filled. There may be a leak that requires repair.
Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.
Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The ORP is connected but turned off. Also the ORP reader does not match our manual test.
Correction: Maintain the pool equipment. Repair and adjust ORP reader.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
AIR MOVEMENT
Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. There is significant condensation build up on the ceiling and the windows. This is an indication the facility does not have proper ventilation.
Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.
Code ATCP 76.33(4)(b) - AIR MOVEMENT
-
Not serious
Non-critical
Repeat
-
Mar 29, 2024 Routine · 1 critical, 8 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir door missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
WATER LEVEL-SKIMMERS MAINTAINED
Water level in a skimmer pool is not allowing for effective skimming. The water level is too high.
Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.
Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing for combined chlorine and alkalinity.
Correction: Record the following on the operating report, results for chemical testing for combined chlorine and alkalinity.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
POOL DECK-INDOOR-DISINFECTED
Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions. The pool deck is dirty and has pooling water around the pool. The water is not effectively draining. At the time of the inspection, the pool was filled too high and spilling on to the deck. The person in charge indicated that the pool loses 8 inches of water each day and needs to be refilled. Sometimes the pool is over filled. There may be a leak that requires repair.
Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.
Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The ORP is connected but turned off. Also the ORP reader does not match our manual test.
Correction: Maintain the pool equipment. Repair and adjust ORP reader.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
AIR MOVEMENT
Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. There is significant condensation build up on the ceiling and the windows. This is an indication the facility does not have proper ventilation.
Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.
Code ATCP 76.33(4)(b) - AIR MOVEMENT
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. The pool shall close to the public until a working phone is in place. The pool may reopen to the public prior to reinspection provided there is a working phone. Contact the North Shore Health Department when phone is installed and working.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
Source: North Shore Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.