YearInspectionsViolationsSerious
2026122
2025283
2023110

Inspections

  1. May 4, 2026 Routine · 2 critical
    • Serious Critical

      PH

      The pH is above 8.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      MAXIMUM BROMINE

      The maximum total bromine exceeds 10 ppm.

      Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.

      Code ATCP 76.14(5)(g) -MAXIMUM BROMINE

  2. Feb 20, 2025 Re-inspection · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      SKIMMERS MAINTAINED CLEAN

      Skimmer had a build up of what appeared to be mold on the inside.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

  3. Feb 6, 2025 Routine · 3 critical, 4 non-critical
    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Skimmer had a build up of what appeared to be mold on the inside.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer does not have a weir door.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical Corrected on site

      RECIRCULATION SYSTEM CONTINUOUS OPERATION

      The pool recirculation system is not operational where the skimmers were not operational.

      Correction: The skimmers were not turned back on after conducting work on the pool today. The skimmers were reactivated. It was recommended at the time of the inspection that the pool remain closed to complete one full turnover. The pool operator agreed to do so.

      Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O

    • Serious Critical

      AUTOMATIC AND CONTINUOUS DISINFECTION

      Pool not automatically disinfected. During the inspection it was found that pucks were placed in the skimmer baskets.

      Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13. The pucks were removed at the time of the inspection. Do not place pucks in the baskets.

      Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 3.5 ppm for bromine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  4. Oct 3, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 20 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY