Milwaukee Country Club
8000 N RANGE LINE, River Hills, WI 53217 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- North Shore Health Department
- License / ID
- SYOG-7QRUW5
- Status
- Permitted
- Phone
- (414) 362-5200
- Official record
- North Shore Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 1 |
| 2025 | 1 | 3 | 0 |
| 2024 | 2 | 4 | 1 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Aug 19, 2026 Routine · 1 critical, 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is [615] mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is [0 ppm ] for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Minimum amount required is 1 ppm. Pool adjusted to 8.5 ppm during the inspection.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
Repeat
-
Aug 6, 2025 Routine · 3 non-critical, 1 repeat
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. The combine chlorine plan template will be sent by the NSHD.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is [560] mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
-
Aug 14, 2024 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is [495 ] mV and water has not been tested manually. The ORP was increasing at the time of inspection.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is [0.5 ppm]. The Chlorine was raised to 3.5 ppm at the time of the inspection
Correction: Maintain chlorine level above 1.0 ppm.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
-
May 24, 2024 Pre-inspection · 2 non-critical
-
Not serious
Non-critical
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The shower, toilet and dressing facilities are under construction. Millwork is being completed. The toilet, shower, sinks are functioning.
Correction: Complete construction. The counter top is to be installed June 3rd.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool area is under construction and the pool shall not open until construction is complete and area is cleaned.
Correction: Finish construction and clean deck area prior to opening.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
-
Jun 20, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The flowmeter is not functional because sand was stuck in the tube.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Source: North Shore Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.