RecordWell Data

Northpoint Apartments

9418 N GREEN BAY, Brown Deer, WI 53209 · Milwaukee County

7cited violations
4serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
North Shore Health Department
License / ID
SYOG-7QRUW4
Status
Permitted
Phone
(414) 355-3501
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026132
2025122
2023120

Inspections

  1. Jun 24, 2026 Routine · 2 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Corrected on site

      ALKALINITY

      The total alkalinity was at 30 ppm at start of inspection. Pool operator added bicarbonate, and alkalinity was 180 at conclusion of inspection.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical Repeat Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 2.0 for chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Chlorine was adjusted and measured 5.0 at conclusion of inspection.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Repeat Corrected on site

      PH

      The pH is 7.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better. pH was adjusted and was at 7.4 at conclusion of inspection.

      Code ATCP 76.14(5)(c) - PH

  2. Feb 4, 2025 Routine · 2 critical
    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is [3.0 ppm ] for chlorine in a whirlpool and it was found at 1.0 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is [7.0 ].

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  3. Sep 1, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      WATER TESTING FREQUENCY - WHIRLPOOL, THERAPY POOL, EXERCISE POOL

      According to pool logs, the water testing frequency for chemicals is not in compliance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2).

      Code ATCP 76.18(2)

    • Not serious Non-critical

      CRACKS OR PITTING IN THE POOL BASIN

      The pool basin is cracked, pitted or damaged.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code [B] ATCP 76.33(1)(a)

Source: North Shore Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.