RecordWell Data

Elite Sports Club - North Shore Mens Whirlpool

5750 N GLEN PARK RD, Glendale, WI 53209 · Milwaukee County

21cited violations
2serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
North Shore Health Department
License / ID
BSIY-BKFPCU
Status
Permitted
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20253162
2023250

Inspections

  1. Jan 28, 2025 Re-inspection · 1 critical, 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer basket not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Chlorine level is 0 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Close the pool until the chlorine is between 3 ppm and 10 ppm.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  2. Jan 27, 2025 Re-inspection · 1 critical, 5 non-critical, 5 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer basket not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Not serious Non-critical Repeat

      ELECTRICAL GOOD REPAIR

      The pump has a leak.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

    • Serious Critical

      INTERLOCKED-ELECTRICAL

      Power to recirculation system is not interlocked with the power to the chemical feed.

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s). Close the pool until the interlock system has been put in place.

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

  3. Jan 17, 2025 Routine · 6 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer basket not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      WATER LEVEL-SKIMMERS MAINTAINED

      Water level in a skimmer pool is not allowing for effective skimming because the water level is too high.

      Correction: Maintain the water level in the pool so that the skimmer weir is half submerged.

      Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Not serious Non-critical

      ELECTRICAL GOOD REPAIR

      The pump has a leak.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

  4. May 5, 2023 Re-inspection · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION RATE NOT MET - WHIRLPOOLS

      The whirlpool has a maximum turnover rate of greater than 30 minutes and is at 40 minutes.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(d)

    • Not serious Non-critical Repeat

      WATER LEVEL TOO LOW

      The pool water level is not adequate for continuous effective surface skimming. The water level is too high

      Correction: Raise the water level until the skimming of the water surface is adequate.

      Code [B] ATCP 76.11(2)(a)

  5. May 1, 2023 Re-inspection · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION RATE NOT MET - WHIRLPOOLS

      The whirlpool has a maximum turnover rate of greater than 30 minutes and is at 40 minutes.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(d)

    • Not serious Non-critical Repeat

      CHEMICAL LABELING

      Chlorine container not labeled is not labeled according to ATCP 76.12(1).

      Correction: Label the chemical container according to ATCP 76.12(1).

      Code ATCP 76.12(1)

    • Not serious Non-critical Repeat

      WATER LEVEL TOO LOW

      The pool water level is not adequate for continuous effective surface skimming. The water level is too high

      Correction: Raise the water level until the skimming of the water surface is adequate.

      Code [B] ATCP 76.11(2)(a)

Source: North Shore Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.