Four Points By Sheraton Milwaukee North - Outdoor Pool
8900 N KILDEER CT, Brown Deer, WI 53209 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- North Shore Health Department
- License / ID
- ASCT-BMJKZS
- Status
- Permitted
- Official record
- North Shore Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 12 | 4 |
| 2025 | 2 | 14 | 7 |
| 2024 | 2 | 10 | 1 |
| 2023 | 1 | 4 | 0 |
Inspections
-
Sep 24, 2026 Routine · 4 critical, 8 non-critical, 5 repeat
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
Skimmers not adjusted to ensure vigorous skimming. One skimmer is sealed to prevent the flow of water.
Correction: Adjust skimmers to maintain vigorous skimming. Unseal the skimmer.
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers full of leaves and chlorine pucks.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is [202] mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
POOL RULES POSTED
The pool rules are not posted.
Correction: Post the pool rules.
Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Missing tile on stairs and walls.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
AUTOMATIC AND CONTINUOUS DISINFECTION
Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. Facility placing chlorine pucks in the skimmer baskets.
Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13.
Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.5 ppm chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
RING BOUY
A ring buoy not provided.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications. Obtained pump curve online at the time of the inspection.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers. Keep pump curve available.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Aug 4, 2025 Re-inspection · 2 critical, 2 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The flow meter is at 30 gpm. The pool is 16,000 gallons. The flow rate is 8.8 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate at 6 hours. Facility requested 60 days to replace the pumps.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
The emergency phones do not dial 911 and instead call the front desk.
Correction: Provide a reliable service connection for the communication technology. The facility may obtain a variance for not connecting directly to 911 or make the connection.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Jul 21, 2025 Routine · 5 critical, 5 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The flow meter is at 30 gpm. The pool is 16,000 gallons. The flow rate is 8.8 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate at 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the chemical tests for the month of July.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
Corrected on site
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The handrail was loose and was repaired at the time of the inspection.
Correction: Maintain the pool equipment.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is [0 ppm] for chlorine
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
RING BOUY
A ring buoy not provided. Ring bouy provided during the inspection.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
The emergency phones do not dial 911 and instead call the front desk.
Correction: Provide a reliable service connection for the communication technology. The facility may obtain a variance for not connecting directly to 911 or make the connection.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Serious
Critical
Corrected on site
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The housing for the one of the underwater lights was loose and I was able to pull it from the wall. The facility also added chlorine pucks to the each basket in the skimmer.
Correction: The operator repaired the light at the time of the inspection. The pucks were removed at the time of the inspection.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Jul 11, 2024 Re-inspection · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE
The flowmeter is not installed according to manufacturer instructions or as verified by pump curve. No flowmeter present
Correction: Install the flowmeter according to manufacturer instructions or as verified by pump curve. FLOWMETER ORDERED AND WILL SEND PICTURE WHEN INSTALLED.
Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO
-
Not serious
Non-critical
Repeat
POOL RULES LETTER OR SYMBOL SIZE
Pool rules letters are less than one inche in height.
Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height. SIGN ORDERED AND WILL SEND PICTURE WHEN HUNG.
Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE
-
Not serious
Non-critical
Repeat
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
-
Jun 27, 2024 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE
The flowmeter is not installed according to manufacturer instructions or as verified by pump curve. No flowmeter present
Correction: Install the flowmeter according to manufacturer instructions or as verified by pump curve.
Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POOL RULES LETTER OR SYMBOL SIZE
Pool rules letters are less than one inche in height.
Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.
Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Serious
Critical
HOSING - BACKFLOW PREVENTION DEVICE
Air gap not provided for discharge piping and it is extending beyond flood-rim for backwash.
Correction: Provide an air gap according to plumbing code.
Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION
-
Not serious
Non-critical
-
Aug 7, 2023 Routine · 4 non-critical, 1 repeat
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
No flowmeter present at the time of the inspection.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is [>8.0 ].
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
HAZARDOUS OBJECT OR MATERIAL IN THE POOL AREA
A disinfection feeder was added to the return line at the time of the inspection.
Correction: Remove feeder from the pool.
Code ATCP 76.34(1)
-
Not serious
Non-critical
Repeat
CHLORINE TOO LOW
The chlorine residual was [0.6 ppm] at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to [3.0 ppm] before re-opening.
Code [A] ATCP 76.14(4)(a)
-
Not serious
Non-critical
Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.