Four Points By Sheraton Milwaukee North - Outdoor Pool

8900 N KILDEER CT, Brown Deer, WI 53209 · Milwaukee County

40cited violations
12serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
North Shore Health Department
License / ID
ASCT-BMJKZS
Status
Permitted
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261124
20252147
20242101
2023140

Inspections

  1. Sep 24, 2026 Routine · 4 critical, 8 non-critical, 5 repeat
    • Not serious Non-critical

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. One skimmer is sealed to prevent the flow of water.

      Correction: Adjust skimmers to maintain vigorous skimming. Unseal the skimmer.

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Skimmers full of leaves and chlorine pucks.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is [202] mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      POOL RULES POSTED

      The pool rules are not posted.

      Correction: Post the pool rules.

      Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED

    • Not serious Non-critical Repeat

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Missing tile on stairs and walls.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      AUTOMATIC AND CONTINUOUS DISINFECTION

      Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. Facility placing chlorine pucks in the skimmer baskets.

      Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13.

      Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION

    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.5 ppm chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Repeat

      RING BOUY

      A ring buoy not provided.

      Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications. Obtained pump curve online at the time of the inspection.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers. Keep pump curve available.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  2. Aug 4, 2025 Re-inspection · 2 critical, 2 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The flow meter is at 30 gpm. The pool is 16,000 gallons. The flow rate is 8.8 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate at 6 hours. Facility requested 60 days to replace the pumps.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Repeat

      TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION

      The emergency phones do not dial 911 and instead call the front desk.

      Correction: Provide a reliable service connection for the communication technology. The facility may obtain a variance for not connecting directly to 911 or make the connection.

      Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Jul 21, 2025 Routine · 5 critical, 5 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The flow meter is at 30 gpm. The pool is 16,000 gallons. The flow rate is 8.8 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate at 6 hours.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the chemical tests for the month of July.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Corrected on site

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool equipment is not properly maintained. The handrail was loose and was repaired at the time of the inspection.

      Correction: Maintain the pool equipment.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is [0 ppm] for chlorine

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Corrected on site

      RING BOUY

      A ring buoy not provided. Ring bouy provided during the inspection.

      Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

    • Serious Critical

      TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION

      The emergency phones do not dial 911 and instead call the front desk.

      Correction: Provide a reliable service connection for the communication technology. The facility may obtain a variance for not connecting directly to 911 or make the connection.

      Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI

    • Serious Critical Corrected on site

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. The housing for the one of the underwater lights was loose and I was able to pull it from the wall. The facility also added chlorine pucks to the each basket in the skimmer.

      Correction: The operator repaired the light at the time of the inspection. The pucks were removed at the time of the inspection.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Jul 11, 2024 Re-inspection · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE

      The flowmeter is not installed according to manufacturer instructions or as verified by pump curve. No flowmeter present

      Correction: Install the flowmeter according to manufacturer instructions or as verified by pump curve. FLOWMETER ORDERED AND WILL SEND PICTURE WHEN INSTALLED.

      Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO

    • Not serious Non-critical Repeat

      POOL RULES LETTER OR SYMBOL SIZE

      Pool rules letters are less than one inche in height.

      Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height. SIGN ORDERED AND WILL SEND PICTURE WHEN HUNG.

      Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE

    • Not serious Non-critical Repeat

      PIPING LABELED, TAGGED OR CODED

      The piping is not labeled, tagged or color-coded.

      Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.

      Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

  5. Jun 27, 2024 Routine · 1 critical, 5 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE

      The flowmeter is not installed according to manufacturer instructions or as verified by pump curve. No flowmeter present

      Correction: Install the flowmeter according to manufacturer instructions or as verified by pump curve.

      Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO

    • Not serious Non-critical

      PIPING LABELED, TAGGED OR CODED

      The piping is not labeled, tagged or color-coded.

      Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.

      Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POOL RULES LETTER OR SYMBOL SIZE

      Pool rules letters are less than one inche in height.

      Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.

      Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Serious Critical

      HOSING - BACKFLOW PREVENTION DEVICE

      Air gap not provided for discharge piping and it is extending beyond flood-rim for backwash.

      Correction: Provide an air gap according to plumbing code.

      Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION

  6. Aug 7, 2023 Routine · 4 non-critical, 1 repeat
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      No flowmeter present at the time of the inspection.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical

      pH OUT OF BALANCE

      The pH is [>8.0 ].

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Non-critical

      HAZARDOUS OBJECT OR MATERIAL IN THE POOL AREA

      A disinfection feeder was added to the return line at the time of the inspection.

      Correction: Remove feeder from the pool.

      Code ATCP 76.34(1)

    • Not serious Non-critical Repeat

      CHLORINE TOO LOW

      The chlorine residual was [0.6 ppm] at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [3.0 ppm] before re-opening.

      Code [A] ATCP 76.14(4)(a)

Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.