RecordWell Data

Holiday Inn Express

4443 W SCHROEDER, Brown Deer, WI 53223 · Milwaukee County

44cited violations
6serious tier
9inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
North Shore Health Department
License / ID
MWIN-7R4KP6
Status
Permitted
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026210
20255294
20242142

Inspections

  1. Feb 27, 2026 Admin Follow Up · No items found

    No violations cited.

  2. Feb 20, 2026 Routine · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

  3. Jun 18, 2025 Re-inspection · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Multiple areas of pool basin are pitted.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

  4. Jun 16, 2025 Re-inspection · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      Pools having 2 or more reinspections in a 3-year period are required to have a certified operator. Re-inspections have been required for pool in 2024 and 2025. 5/16/25 - At re-inspection, person in charge stated pool operator has taken CPO exam twice and did not receive passing score. Next test date is 6/11/2025.

      Correction: Provide a certified operator for the pool within 90 days.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Multiple areas of pool basin are pitted.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

  5. May 16, 2025 Re-inspection · 1 critical, 5 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      Pools having 2 or more reinspections in a 3-year period are required to have a certified operator. Re-inspections have been required for pool in 2024 and 2025. 5/16/25 - At re-inspection, person in charge stated pool operator has taken CPO exam twice and did not receive passing score. Next test date is 6/11/2025.

      Correction: Provide a certified operator for the pool within 90 days.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Not serious Non-critical Repeat

      POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK

      Pool rules missing rule: Diaper changing on the pool deck is prohibited.

      Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited. 5/16/25 - At re-inspection, person in charge provided invoice showing sign has been ordered.

      Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding. 5/16/25 - At re-inspection, person in charge provided invoice showing sign has been ordered.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Multiple areas of pool basin are pitted.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical Repeat

      CHEMICAL STORAGE LOCATION

      Liquid chlorine and acid not stored in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources. Pool chemicals are stored in outdoor storage box with gasoline, the liquid chlorine barrel is uncapped, and the outdoor storage box is unlocked. 5/16/25 - At re-inspection, gasoline no longer stored with pool chemicals. Outdoor storage box still not locked as locking mechanism is broken and acid barrel is uncapped.

      Correction: Store all chemicals in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources. Cap and secure pool chemicals in locked area.

      Code ATCP 76.12 (2)(b) - CHEMICAL STORAGE LOCATION

  6. Feb 13, 2025 Re-inspection · 1 critical, 8 non-critical, 9 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed. Weir door is missing on one of the skimmers.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      Pools having 2 or more reinspections in a 3-year period are required to have a certified operator. Re-inspections have been required for pool in 2024 and 2025.

      Correction: Provide a certified operator for the pool within 90 days.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Not serious Non-critical Repeat

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical Repeat

      POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK

      Pool rules missing rule: Diaper changing on the pool deck is prohibited.

      Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited.

      Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Multiple areas of pool basin are pitted.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical Repeat

      CHEMICAL STORAGE LOCATION

      Liquid chlorine and acid not stored in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources. Pool chemicals are stored in outdoor storage box with gasoline, the liquid chlorine barrel is uncapped, and the outdoor storage box is unlocked.

      Correction: Store all chemicals in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources.

      Code ATCP 76.12 (2)(b) - CHEMICAL STORAGE LOCATION

  7. Feb 11, 2025 Routine · 2 critical, 9 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed. Weir door is missing on one of the skimmers.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      Pools having 2 or more reinspections in a 3-year period may be required to have a certified operator. Re-inspections have been required for pool in 2024 and 2025.

      Correction: Provide a certified operator for the pool within 90 days.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK

      Pool rules missing rule: Diaper changing on the pool deck is prohibited.

      Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited.

      Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Multiple areas of pool basin are pitted.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical

      CHEMICAL STORAGE LOCATION

      Liquid chlorine and acid not stored in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources. Pool chemicals are stored in outdoor storage box with gasoline, the liquid chlorine barrel is uncapped, and the outdoor storage box is unlocked.

      Correction: Store all chemicals in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources.

      Code ATCP 76.12 (2)(b) - CHEMICAL STORAGE LOCATION

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.4 for liquid chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  8. Feb 26, 2024 Re-inspection · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer weir missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks.

      Correction: Maintained the pool basin free of cracks or other defects. Repair the basin of the pool to be cleanable.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

  9. Feb 21, 2024 Routine · 2 critical, 8 non-critical
    • Not serious Non-critical

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is fully open.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer weir missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      VENTILATION

      pH plus, chlorine pucks and other chemicals were stored in the pump room. This area is not well ventilated. The facility stores liquid chemicals outside.

      Correction: Provide ventilation for this room or move chemicals to a safe, dry location that is well ventilated.

      Code ATCP 76.12 (2)(h) - VENTILATION SPS 364

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      RESCUE EQUIPMENT ACCESSIBLE

      The rescue equipment is not readily accessible. The rope for the ring buoy is tied and/or wrapped.

      Correction: Maintain rescue equipment to be easily accessible.

      Code ATCP 76.26(1)(a)2. - RESCUE EQPT ACCESSIBLE

    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks.

      Correction: Maintained the pool basin free of cracks or other defects. Repair the basin of the pool to be cleanable.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Not serious Non-critical

      POOL EQUIPMENT-REPAIRED AS NECESSARY

      The pool equipment is not repaired as necessary. Gauges not functional, filter is leaking, ORP is in alarm, chemical feed system not functioning.

      Correction: The pool equipment is not repaired as necessary. Repair and maintain equipment.

      Code ATCP 76.33(1)(e)4. - EQPT REPAIRED AS NEEDED

    • Serious Critical

      AUTOMATIC AND CONTINUOUS DISINFECTION

      Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. The chemical feed system is not functioning and chlorine pucks are being manually added to the pool.

      Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13. Repair chemical feed system and discontinue added chlorine to the water manually.

      Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION

    • Serious Critical

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm. The chlorine is at 44 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.