Chiswick Apartments

7700 N PORT WASHINGTON RD, Fox Point, WI 53217 · Milwaukee County

18cited violations
7serious tier
8inspections

Establishment

Type
Pool / recreational water (Pool - Simple with Features)
Inspected by
North Shore Health Department
License / ID
BSIY-BC7M4A
Status
Permitted
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2025363
2024242
2023252

Inspections

  1. Aug 4, 2026 Routine · 3 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 614 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

  2. Jul 17, 2025 Re-inspection · No items found

    No violations cited.

  3. Jul 15, 2025 Re-inspection · 1 critical, 1 repeat
    • Serious Critical Repeat

      DRINKING FOUNTAIN PROVIDED

      Drinking fountain in pool area is not working.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  4. Jul 8, 2025 Routine · 2 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Reagents in test kit are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical Corrected on site

      SHEPHERD'S CROOK PROVIDED

      The shepherd's crook is missing.

      Correction: Provide a shepherd's crook. Shepherd's crook was retrieved from storage during the inspection and placed in an accessible location in the pool area.

      Code ATCP 76.26(1)(b)1.a. -SHEPHERED'S CROOK PROVIDED

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      Drinking fountain in pool area is not working.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  5. Sep 4, 2024 Re-inspection · No items found

    No violations cited.

  6. Aug 14, 2024 Routine · 2 critical, 2 non-critical
    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      RESCUE EQUIPMENT GOOD REPAIR

      The rescue equipment is not in good repair. Rope for ring buoy is missing. Facility has a shepherd's crook and ring buoy available for rescue.

      Correction: Maintain all rescue equipment in good repair.

      Code ATCP 76.26(1)(a)1. - RESCUE EQPT GOOD REPAIR

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  7. Aug 4, 2023 Re-inspection · 1 critical, 1 repeat
    • Serious Critical Repeat

      WATER POTENTIAL OUT OF RANGE

      The water potential was [602 ] mV at the time of the inspection and the unit was in alarm. 8/4/2023 - At re-inspection, water potential reading on ORP meter was 613 mV. Accepted range is 650-850 mV.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed.

      Code ATCP 76.14(5)(a)

  8. Jul 28, 2023 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      CYANURIC ACID >30 PPM

      The cyanuric acid concentration is [40 ppm].

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Non-critical

      RESCUE EQUIPMENT NOT ACCESSIBLE

      The shepherds hook is not hung for easy access. The hook is on the ground behind a table. The rope for the ring buoy is tied in a knot.

      Correction: Mount shepherds hook in a readily accessible location. Keep the rope for the ring buoy loose.

      Code ATCP 76.26(1)(a)

    • Not serious Non-critical

      SIGNAGE - LETTERS TOO SMALL

      The letters on the pool rules signage are less than 1-inch in height.

      Correction: Reprint the sign in compliance with ATCP 76.29(1)(b).

      Code [A] ATCP 76.29(1)(b)

    • Serious Critical

      WATER POTENTIAL OUT OF RANGE

      The water potential was [602 ] mV at the time of the inspection and the unit was in alarm.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed.

      Code ATCP 76.14(5)(a)

Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.