Hampton Inn Glendale
7065 N PORT WASHINGTON RD, Glendale, WI 53217 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- North Shore Health Department
- License / ID
- HPOL-BSCQNM
- Status
- Permitted
- Official record
- North Shore Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 1 |
| 2025 | 1 | 5 | 1 |
| 2024 | 3 | 15 | 2 |
Inspections
-
Apr 14, 2026 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
-
Mar 31, 2025 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmer baskets not maintained clean.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Several test kit reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Serious
Critical
Corrected on site
GATES AND DOORS-LATCHING
At time of inspection, exterior door to pool did not latch.
Correction: Provide a latching door. During inspection, maintenace employee was able to repair automatic door closer so that exterior door latched.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
-
Jun 6, 2024 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart. Person in charge stated filter is "backwashed daily," which is not likely the correct manufacturer recommendation.
Correction: Post the backwash procedure on an easily read chart. Backwash filter as recommended by the manufacturer.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
-
May 2, 2024 Re-inspection · 1 critical, 5 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE
The flow meter is not installed according to manufacturer instructions. It has been installed upside down and gauge is not functioning.
Correction: Install the flow meter according to manufacturer instructions or as verified by pump curve.
Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO
-
Not serious
Non-critical
Repeat
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart. Person in charge stated filter is "backwashed daily," which is not likely the correct manufacturer recommendation.
Correction: Post the backwash procedure on an easily read chart. Backwash filter as recommended by the manufacturer.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
ELECTRICAL GOOD REPAIR
Electrical equipment and lighting not maintained in good repair and in operating condition. There is an exposed electrical wire in the circular hole for recessed light in ceiling above spectator area of the pool room.
Correction: Maintain electrical equipment and lighting in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Serious
Critical
Repeat
RING BOUY
Rope on ring bouy is too short.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Not serious
Non-critical
Repeat
-
Apr 25, 2024 Routine · 1 critical, 6 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE
The flow meter is not installed according to manufacturer instructions. It has been installed upside down and gauge is not functioning.
Correction: Install the flow meter according to manufacturer instructions or as verified by pump curve.
Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart. Person in charge stated filter is "backwashed daily," which is not likely the correct manufacturer recommendation.
Correction: Post the backwash procedure on an easily read chart. Backwash filter as recommended by the manufacturer.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing of free chlorine and combined chlorine. For several dates (approximately 11 days for current month), test results were not recorded at all. Unable to verify chemical testing was done on those dates.
Correction: Record the following on the operating report: 1. Daily results for chemical testing of free chlorine and pH prior to pool opening. 2. Test and record combined chlorine at least twice weekly. 3. Test and record alkalinity at least once weekly. 4. Complete pump safety checks monthly and record on log. Refer to DATCP Operating Report for Pools with Controllers template for testing requirements.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
ELECTRICAL GOOD REPAIR
Electrical equipment and lighting not maintained in good repair and in operating condition. There is an exposed electrical wire in the circular hole for recessed light in ceiling above spectator area of the pool room.
Correction: Maintain electrical equipment and lighting in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Serious
Critical
RING BOUY
Rope on ring bouy is too short.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Not serious
Non-critical
Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.