RecordWell Data

Tripoli Country Club

7401 N 43 ST, Brown Deer, WI 53223 · Milwaukee County

27cited violations
2serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Moderate with Features)
Inspected by
North Shore Health Department
License / ID
BSIY-ANSJDU
Status
Permitted
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026150
20252162
2024140
2023220

Inspections

  1. Aug 11, 2026 Routine · 5 non-critical, 3 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is [40 ppm].

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical Repeat

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

  2. Oct 1, 2025 Re-inspection · 6 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week. It is tested monthly.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical Repeat

      LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED

      No lifeguard and attendant staffing plan is available.

      Correction: Prepare and maintain a lifeguard staffing plan.

      Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR

    • Not serious Non-critical Repeat

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone. .

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical Repeat

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

  3. Aug 27, 2025 Routine · 2 critical, 8 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 597 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week. It is tested monthly.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED

      No lifeguard and attendant staffing plan is available.

      Correction: Prepare and maintain a lifeguard staffing plan.

      Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR

    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone. .

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      CO ALARM-POOL AREA

      There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.

      Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications for existing covers. If pool is reverse flow, provide a letter from a professional engineer or other knowledgeable pool professional that states the pool is reverse flow and therefore compliant with VGBA regulations.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Aug 14, 2024 Routine · 4 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is [40 ppm ].

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      INCREASED TESTING MAY BE REQUIRED

      Testing for cyanuric acid, combined chlorine and alkalinity are not being logged.

      Correction: Routinely test and log .

      Code ATCP 76.18(4) - INCREASED TESTING

    • Not serious Non-critical

      MAX PATRON LOAD POOL

      Patron load not posted.

      Correction: Calculate the maximum patron load to provide at least 15 square feet per patron in the shallow portion and 25 square feet per patron in the deep portion and do not allow maximum patron load to be exceeded.

      Code ATCP 76.25(2)(a) - POOL

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  5. Aug 4, 2023 Re-inspection · No items found

    No violations cited.

  6. Jul 27, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Records not available for review.

      Code ATCP 76.18(1)

    • Not serious Non-critical

      CHLORINE TOO LOW

      The chlorine residual was [.5 ppm ] at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [1.0 ppm ] before re-opening.

      Code [A] ATCP 76.14(4)(a)

Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.