Elite Sports Club - River Glen Exercise Pool
2001 W GOOD HOPE RD, Glendale, WI 53209 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- North Shore Health Department
- License / ID
- BSIY-BKFR7Z
- Status
- Permitted
- Official record
- North Shore Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 8 | 1 |
| 2025 | 2 | 5 | 1 |
| 2024 | 2 | 7 | 0 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Aug 7, 2026 Re-inspection · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in exercise pool and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Exercise pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
Repeat
-
Jul 21, 2026 Routine · 1 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate for an exercise pool is 4 hours
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 4 hours. Otherwise, provide documentation that the pool was designed to operate at a different rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in exercise pool and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Exercise pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Serious
Critical
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
Emergency phone in exercise pool is not functional.
Correction: Close the pool until there is a working emergency phone. Reinspection required. A temporary phone has been installed until the new phone system is installed.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Not serious
Non-critical
Repeat
-
Aug 22, 2025 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The pool is 27,000 gallons and the flow meter reads 50 gpm which is a 9 hour turnover rate.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
-
Aug 15, 2025 Routine · 1 critical, 3 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The pool is 27,000 gallons and the flow meter reads 50 gpm which is a 9 hour turnover rate.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Serious
Critical
LIFEGUARD AND ATTENDANT STAFFING REQUIREMENTS, TABLES A AND B
The pool is not adequately staffed. An exercise class was not staffed with a lifeguard.
Correction: Staff the pool with adequate numbers of properly-credentialed lifeguards and attendants.
Code ATCP 76.23(1)(a)1 - LIFEGUARDS OR ATTENDANTS PRESENT WHERE R
-
Not serious
Non-critical
Repeat
-
Aug 8, 2024 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS MAINTAINED CLEAN
Skimmers are not maintained clean. There was a build up of dirt under the skimmer cover.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Jul 31, 2024 Routine · 5 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers are not maintained clean. There was a build up of dirt under the skimmer cover.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The exercise pool has 465 gallons per person at a temperature of 89.7 F. Code requires a turnove rate of 2 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 2 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
Pressure guage not functional on filter
Correction: Adjust or repair the pressure guage.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
-
Jun 27, 2023 Routine · 2 non-critical
-
Not serious
Non-critical
MISSING RESCUE EQUIPMENT
Ring buoy does not have a rope attacehd to it.
Correction: Provide rope according to code for the ring buoy.
Code ATCP 76.26(1)(b)
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
Weir doors missing for the skimmers.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.