YearInspectionsViolationsSerious
2026110
2025243
2024162

Inspections

  1. Jul 28, 2026 Routine · 1 non-critical
    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The VGBA log or other proof does not indicate drain cover life span.

      Correction: Indicate in the log the drain cover life span. Documentation on the drain cover or if it is installed according to the manufactures specifications is not available.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

  2. Aug 6, 2025 Re-inspection · No items found

    No violations cited.

  3. Jul 29, 2025 Routine · 3 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Serious Critical Repeat

      PH

      The pH is [ >8.0].

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      RING BOUY

      The ring buoy rope was brittle and easily broke.

      Correction: Replace rope. Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

    • Serious Critical

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      Close the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone. The pool may reopen once the phone is operational and has been tested.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  4. Aug 13, 2024 Routine · 2 critical, 4 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Turnover rate is over 6 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      INTERLOCKED-ELECTRICAL

      Power to recirculation system is not interlocked with the power to the chemical feed.

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding. Sign is on order.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      PH

      The pH is [8.0 ].

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION

      Phone does not have reliable service connection. The phone dails out but does not connect.

      Correction: Provide a reliable service connection for the communication technology.

      Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI

Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.