The Glen (swimming Pool)

7275 N PORT WASHINGTON RD, Glendale, WI 53217 · Milwaukee County

33cited violations
3serious tier
7inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
North Shore Health Department
License / ID
RGON-ACYHKE
Status
Permitted
Phone
(414) 352-0070
Official record
North Shore Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2025281
20242122
20232100

Inspections

  1. Jul 20, 2026 Routine · 3 non-critical
    • Not serious Non-critical

      FIRST AID KIT -RESUSCITATION POCKET MASK

      The first aid kit is missing a resuscitation pocket mask.

      Correction: Provide a resuscitation pocket mask for the first aid kit.

      Code ATCP 76.27(1)(b)8.- RESUSCITATION MASK

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

  2. Jul 29, 2025 Re-inspection · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Some of the test kit reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

  3. Jul 18, 2025 Routine · 1 critical, 5 non-critical, 1 repeat
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Some of the test kit reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical Repeat

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. There is no documentation of the equalizer covers being VGBA compliant or within their lifespan.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  4. Sep 13, 2024 Re-inspection · 5 non-critical, 5 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      The floating skimmer not functioning as intended. The weight to keep the floating weir in place was missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not working.

      Correction: Repair or replace the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests. Health Department will provide the log.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  5. Sep 11, 2024 Routine · 2 critical, 5 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      The floating skimmer not functioning as intended. The weight to keep the floating weir in place was missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not working.

      Correction: Repair or replace the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests. Health Department will provide the log.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      PH

      The pH is [ ].

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The pool does not have a nonfunctional emergency phone.

      Correction: Close the pool until repair is made..

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  6. Jul 6, 2023 Re-inspection · 4 non-critical, 3 repeat
    • Not serious Non-critical

      SKIMMER BASKET OR WEIR MISSING

      Weirs are missing.

      Correction: Replace the missing equipment. The use of a floating weir is an option. The main drain grate is found to be expired. At the time of the inspection, no visible issues were noted with the main drain. It is recommended the facility obtain inspection from a pool company to ensure safety of the drain cover until replaced. The facility shall submit a log to the North Shore Health Department indicating d

      Code [B] ATCP 76.11(2)(b)

    • Not serious Non-critical Repeat

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      Flowmeter not functional.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical Repeat

      RESCUE EQUIPMENT NOT ACCESSIBLE

      First aid kit is not labeled and difficult to recognize.

      Correction: Label first aid kit.

      Code ATCP 76.26(1)(a)

    • Not serious Non-critical Repeat

      CRACKS OR PITTING IN THE POOL BASIN

      Tiles have fallen off and need to be replaced.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code [B] ATCP 76.33(1)(a)

  7. Jun 28, 2023 Routine · 6 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMERS NOT FUNCTIONING

      The skimmer at the north end of the pool is not adequately removing surface debris.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers. The skimmer was closed. Opened during the inspection.

      Code ATCP 76.11(2)(a)

    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      Flowmeter not functional.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical

      RESCUE EQUIPMENT NOT ACCESSIBLE

      First aid kit is not labeled and difficult to recognize.

      Correction: Label first aid kit.

      Code ATCP 76.26(1)(a)

    • Not serious Non-critical

      SELF-CLOSING AND LATCHING GATES

      The door or gate to the pool enclosure is not self-closing or latching.

      Correction: Repair the door immediately so that it is self-closing and latching.

      Code [A] ATCP 76.34(4)

    • Not serious Non-critical

      SKIMMER BASKET OR WEIR MISSING

      Weirs are missing.

      Correction: Replace the missing equipment. The use of a floating weir is an option.

      Code [B] ATCP 76.11(2)(b)

    • Not serious Non-critical

      CRACKS OR PITTING IN THE POOL BASIN

      Tiles have fallen off and need to be replaced.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code [B] ATCP 76.33(1)(a)

Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.