The Glen (swimming Pool)
7275 N PORT WASHINGTON RD, Glendale, WI 53217 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- North Shore Health Department
- License / ID
- RGON-ACYHKE
- Status
- Permitted
- Phone
- (414) 352-0070
- Official record
- North Shore Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 2 | 8 | 1 |
| 2024 | 2 | 12 | 2 |
| 2023 | 2 | 10 | 0 |
Inspections
-
Jul 20, 2026 Routine · 3 non-critical
-
Not serious
Non-critical
FIRST AID KIT -RESUSCITATION POCKET MASK
The first aid kit is missing a resuscitation pocket mask.
Correction: Provide a resuscitation pocket mask for the first aid kit.
Code ATCP 76.27(1)(b)8.- RESUSCITATION MASK
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
-
Jul 29, 2025 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Some of the test kit reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
Repeat
-
Jul 18, 2025 Routine · 1 critical, 5 non-critical, 1 repeat
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Some of the test kit reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. There is no documentation of the equalizer covers being VGBA compliant or within their lifespan.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Sep 13, 2024 Re-inspection · 5 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
The floating skimmer not functioning as intended. The weight to keep the floating weir in place was missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not working.
Correction: Repair or replace the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests. Health Department will provide the log.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
-
Sep 11, 2024 Routine · 2 critical, 5 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
The floating skimmer not functioning as intended. The weight to keep the floating weir in place was missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not working.
Correction: Repair or replace the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests. Health Department will provide the log.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
PH
The pH is [ ].
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The pool does not have a nonfunctional emergency phone.
Correction: Close the pool until repair is made..
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Not serious
Non-critical
-
Jul 6, 2023 Re-inspection · 4 non-critical, 3 repeat
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
Weirs are missing.
Correction: Replace the missing equipment. The use of a floating weir is an option. The main drain grate is found to be expired. At the time of the inspection, no visible issues were noted with the main drain. It is recommended the facility obtain inspection from a pool company to ensure safety of the drain cover until replaced. The facility shall submit a log to the North Shore Health Department indicating d
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
Flowmeter not functional.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Repeat
RESCUE EQUIPMENT NOT ACCESSIBLE
First aid kit is not labeled and difficult to recognize.
Correction: Label first aid kit.
Code ATCP 76.26(1)(a)
-
Not serious
Non-critical
Repeat
CRACKS OR PITTING IN THE POOL BASIN
Tiles have fallen off and need to be replaced.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code [B] ATCP 76.33(1)(a)
-
Not serious
Non-critical
-
Jun 28, 2023 Routine · 6 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMERS NOT FUNCTIONING
The skimmer at the north end of the pool is not adequately removing surface debris.
Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers. The skimmer was closed. Opened during the inspection.
Code ATCP 76.11(2)(a)
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
Flowmeter not functional.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
RESCUE EQUIPMENT NOT ACCESSIBLE
First aid kit is not labeled and difficult to recognize.
Correction: Label first aid kit.
Code ATCP 76.26(1)(a)
-
Not serious
Non-critical
SELF-CLOSING AND LATCHING GATES
The door or gate to the pool enclosure is not self-closing or latching.
Correction: Repair the door immediately so that it is self-closing and latching.
Code [A] ATCP 76.34(4)
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
Weirs are missing.
Correction: Replace the missing equipment. The use of a floating weir is an option.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
CRACKS OR PITTING IN THE POOL BASIN
Tiles have fallen off and need to be replaced.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code [B] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Corrected on site
Source: North Shore Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.