RecordWell Data

Springbrook Cercle

8601 SPRINGBROOK BLVD, Oak Creek, WI 53154 · Milwaukee County

18cited violations
9serious tier
8inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Oak Creek Health Department
License / ID
HSAT-7QXRS3
Status
Permitted
Phone
(414) 764-6123
Official record
Oak Creek Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026231
20254127
2024111
2023120

Inspections

  1. Jun 25, 2026 Follow Up · No items found

    No violations cited.

  2. Jun 23, 2026 Routine · 1 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Reagents observed in the test kit expired in 2024 and 2025.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Serious Critical

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  3. Aug 20, 2025 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

  4. Aug 6, 2025 Follow Up · 2 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Serious Critical Repeat

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the entry pipe to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and entry pipe with a air gap.

      Code ATCP 76.19(1) - PROTECTION

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room and in the room whirlpool room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  5. Jun 11, 2025 Routine · 3 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is over 270ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      MAXIMUM BROMINE

      The maximum total bromine exceeds 10 ppm. Readings were over 22.5ppm when stop titrating water sample.

      Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A. Pool to be drained and refilled.

      Code ATCP 76.14(5)(g) -MAXIMUM BROMINE

    • Serious Critical Repeat

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the entry pipe to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and entry pipe with a air gap.

      Code ATCP 76.19(1) - PROTECTION

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room and in the room whirlpool room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  6. Jun 11, 2025 Follow Up · 2 critical, 1 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Serious Critical Repeat

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the entry pipe to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and entry pipe with a air gap.

      Code ATCP 76.19(1) - PROTECTION

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room and in the room whirlpool room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  7. Jun 18, 2024 Routine · 1 critical
    • Serious Critical

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, makeup tank, surge tank or slurry tank and another approved device does not exist. Needs to be an air gap from the supply inlet to the deposit pipe.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

  8. Jun 15, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      TEST KIT NOT APPROVED

      The test kit used by the facility has not been approved by the department. Currently using the La Motte Color Q kit, which has been removed from the approved test kit list.

      Correction: Replace the test kit with one from the approved list.

      Code ATCP 76.17(1)

    • Not serious Non-critical

      BACKFLOW - WATER SUPPLY

      The potable water supply line is below the overflow point of the receiving basin.

      Correction: Install a proper air gap or a reduced pressure zone backflow assembly on the water supply line. Cut the fill pipe to create an air gap.

      Code ATCP 76.19(1)

Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.