Inspections
-
May 19, 2026 Routine · 1 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
COMBINED CHLORINE PLAN ACTION LEVEL
The combined chlorine plan does not include the combined chlorine action level.
Correction: Includes the combined chlorine action level in the combined chlorine plan.
Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. No testing was documented for the days that Tito is off (Sunday's and Monday's).
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items. Missing are the emergency blankets, adhesive bandages, gauze rooler bandage, adhesive tape, elastic bandages.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Serious
Critical
Repeat
Corrected on site
TELEPHONE ACCESSIBLE
The emergency phone was not working at the time of inspection.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Sep 4, 2025 Follow Up · No items found
No violations cited.
-
Aug 27, 2025 Routine · 4 critical, 1 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water. Waiting for chemical to be delivered from Eco Lab to raise alkalinity.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Serious
Critical
VARIANCE, APPROVED, FOLLOWED
Conditions for a variance have not been followed. Emergency phone is not being tested routinely to verify operational.
Correction: Comply with the terms of the variance.
Code ATCP 76.02(2)(b)1 - VARIANCE, APPROVED, FOLLOWED
-
Serious
Critical
Corrected on site
TELEPHONE ACCESSIBLE
A telephone provided for connection to emergency services was not initially working properly due to volume turned down to low. Could not hear the front desk operator.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. Volume setting was turned up to normal.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The pool main drain cover has expired as of last month.
Correction: Correct the hazardous condition by replacing the main drain cover.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
-
Dec 17, 2024 Routine · 1 critical, 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Some of the tiles are missing, broken, or out of place. Grout and caulking are missing is certain areas.
Correction: Maintain pool deck area in good repair. Replace some tiles and provide grouting or caulking.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
TELEPHONE-LOCATION
The telephone or other approved communication technology is not within 25 feet of pool area. The phone at the pool goes directly to the front desk and the front desk would call 911. Variance approval is needed.
Correction: Obtain a variance approval.
Code ATCP 76.26(2)(c) - TELEPHONE, LOCATION
-
Not serious
Non-critical
Repeat
-
Mar 8, 2024 Follow Up · 1 critical, 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 50.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine on the log sheets for this month and last month has been logged at .1ppm every day but the PIC stated they are shocking the pool 2X week because of heavy usage.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. A template of a plan was given to the PIC.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR PROVIDED WITHIN 90 DAYS OF WHEN REQUIRED
A pool that was required to have a certified operator within 90 days does not yet have a certified operator.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)3 - CERTFIED OPERATOR, 90 DAYS OF NEED FOR O
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. PIC did not have records of life span of drain and equalizer covers. Equalizer covers for the pool and whirlpool have exceeded their life span, according to past inspection information.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Serious
Critical
HAZARDOUS CONDITION
The equalizer covers (2) for the pool have expired. Also, the 2 equalizer covers for the whirlpool have also expired.
Correction: New covers have been ordered.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Mar 6, 2024 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% skimmer and 80% maindrain. PIC changed the settings to 80% skimmer and 20% main drain, as required.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine on the log sheets for this month and last month has been logged at .1ppm every day but the PIC stated they are shocking the pool 2X week because of heavy usage.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. A template of a plan was given to the PIC.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
CERTIFIED OPERATOR PROVIDED WITHIN 90 DAYS OF WHEN REQUIRED
A pool that was required to have a certified operator within 90 days does not yet have a certified operator.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)3 - CERTFIED OPERATOR, 90 DAYS OF NEED FOR O
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. PIC did not have records of life span of drain and equalizer covers. Equalizer covers for the pool and whirlpool have exceeded their life span, according to past inspection information.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Serious
Critical
INDOOR POOL WATER TEMPERATURE
The indoor pool water temperature is 93°F.
Correction: Maintain the pool water temperature between 70°F or 21°C and 90°F or 32°C.
Code ATCP 76.19(4)(b)1 - INDOOR POOL WATER TEMP
-
Not serious
Non-critical
Corrected on site
-
Jul 27, 2023 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
Corrected on site
FIRST AID KIT UNAVAILABLE
A first aid kit is not available in the pool area. A sign was previously used to inform patrons to go the the front desk for first aid supplies.
Correction: Provide a first aid kit in the pool area. A sign was placed at the first aid box to inform patrons to go to the front desk. Due to theft.
Code [A] ATCP 76.27(1)
-
Not serious
Non-critical
Repeat
IN NEED OF CLEANING
The pool is in need of cleaning due to sand from the filters in the bottom of the pool.
Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a).
Code [A] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Corrected on site
Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.