  1. Jun 30, 2026 Routine · 2 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is set at 100% for each valve.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      POOL WATER TESTED PEAK PATRON LOAD, PH AND SANITIZER

      Pool water not tested for pH and disinfectant at least one other time during the day’s peak patron load. Controller has been disconnected and with no controller, twice a day pool water testing is required. Once on opening and again during the afternoon.

      Correction: Test pool water for pH and disinfectant at least one time during the day’s peak patron load.

      Code ATCP 76.18(1)(a)2 - WATER TESTED, SANITIZER, PH, PEAK LOAD P

  2. Jul 1, 2025 Routine · 1 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat Corrected on site

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. Flowmeter was stuck at 125 when first observed. Operator did rap onto the flowmeter and it started working.

      Correction: Keep flow meter working or replace.with new flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Serious Critical Corrected on site

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  3. Jul 2, 2024 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SAFETY DATA SHEET

      A safety data sheet was not available for all the chemicals.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical Repeat

      INTERLOCKED-ELECTRICAL

      Power to recirculation system is not interlocked with the power to the chemical feed. The power to the chemical pumps was changed to another outlet with the use of an extension cord due to the proper outlet GFCI tripping out.

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

  4. Jun 25, 2024 Routine · 1 critical, 6 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter was not functioning properly as it was stuck at the bottom.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      SAFETY DATA SHEET

      A safety data sheet was not available for all the chemicals.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      INTERLOCKED-ELECTRICAL

      Power to recirculation system is not interlocked with the power to the chemical feed. The power to the chemical pumps was changed to another outlet with the use of an extension cord due to the proper outlet GFCI tripping out.

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

    • Not serious Non-critical Corrected on site

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. Information and education was given to the operator.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Corrected on site

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises. Will be sent along with this report.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no water at the drinking fountain. Water was turned off due to a leak.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  5. Jul 11, 2023 Follow Up · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SAND FILTER BACKWASHING

      The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b). Log sheet was indicating backwashing was being done every 2-4 days, irregardless of vacuum pressure increases in the sand filters.

      Correction: Backwash the sand filter in accordance with ATCP 76.11(6)(b).

      Code ATCP 76.11(6)(b)

    • Not serious Non-critical Repeat

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency for water chemistry is not in compliance with ATCP 76.18(1). Water not being tested on weekends.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Non-critical Repeat

      BIOHAZARD KIT UNAVAILABLE

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

  6. Jul 10, 2023 Routine · 5 non-critical, 1 repeat
    • Not serious Non-critical

      SAND FILTER BACKWASHING

      The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b). Log sheet was indicating backwashing was being done every 2-4 days, irregardless of vacuum pressure increases in the sand filters.

      Correction: Backwash the sand filter in accordance with ATCP 76.11(6)(b).

      Code ATCP 76.11(6)(b)

    • Not serious Non-critical

      pH OUT OF BALANCE

      The pH is below 7.0.

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Non-critical Repeat

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency for water chemistry is not in compliance with ATCP 76.18(1). Water not being tested on weekends.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Non-critical

      BIOHAZARD KIT UNAVAILABLE

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Non-critical Corrected on site

      SKIMMER/MAIN DRAIN RATIO INCORRECT

      The skimmer to main drain flow ration is not set correctly.

      Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.

      Code [A] ATCP 76.11(2)(a)

Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.