Southfield
1400 W SOUTHFIELD BLVD, Oak Creek, WI 53154 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Oak Creek Health Department
- License / ID
- JHAN-8RSRQ8
- Status
- Permitted
- Phone
- (414) 766-9600
- Official record
- Oak Creek Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 3 | 1 |
| 2024 | 2 | 9 | 1 |
| 2023 | 2 | 8 | 0 |
Inspections
-
Jun 30, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is set at 100% for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
POOL WATER TESTED PEAK PATRON LOAD, PH AND SANITIZER
Pool water not tested for pH and disinfectant at least one other time during the day’s peak patron load. Controller has been disconnected and with no controller, twice a day pool water testing is required. Once on opening and again during the afternoon.
Correction: Test pool water for pH and disinfectant at least one time during the day’s peak patron load.
Code ATCP 76.18(1)(a)2 - WATER TESTED, SANITIZER, PH, PEAK LOAD P
-
Not serious
Non-critical
Corrected on site
-
Jul 1, 2025 Routine · 1 critical, 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
Corrected on site
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. Flowmeter was stuck at 125 when first observed. Operator did rap onto the flowmeter and it started working.
Correction: Keep flow meter working or replace.with new flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
Repeat
Corrected on site
-
Jul 2, 2024 Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SAFETY DATA SHEET
A safety data sheet was not available for all the chemicals.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
INTERLOCKED-ELECTRICAL
Power to recirculation system is not interlocked with the power to the chemical feed. The power to the chemical pumps was changed to another outlet with the use of an extension cord due to the proper outlet GFCI tripping out.
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
Repeat
-
Jun 25, 2024 Routine · 1 critical, 6 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter was not functioning properly as it was stuck at the bottom.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for all the chemicals.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
INTERLOCKED-ELECTRICAL
Power to recirculation system is not interlocked with the power to the chemical feed. The power to the chemical pumps was changed to another outlet with the use of an extension cord due to the proper outlet GFCI tripping out.
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
Corrected on site
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. Information and education was given to the operator.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Corrected on site
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises. Will be sent along with this report.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no water at the drinking fountain. Water was turned off due to a leak.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
-
Jul 11, 2023 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SAND FILTER BACKWASHING
The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b). Log sheet was indicating backwashing was being done every 2-4 days, irregardless of vacuum pressure increases in the sand filters.
Correction: Backwash the sand filter in accordance with ATCP 76.11(6)(b).
Code ATCP 76.11(6)(b)
-
Not serious
Non-critical
Repeat
WATER TESTING FREQUENCY - POOLS
The water testing frequency for water chemistry is not in compliance with ATCP 76.18(1). Water not being tested on weekends.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT UNAVAILABLE
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Non-critical
Repeat
-
Jul 10, 2023 Routine · 5 non-critical, 1 repeat
-
Not serious
Non-critical
SAND FILTER BACKWASHING
The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b). Log sheet was indicating backwashing was being done every 2-4 days, irregardless of vacuum pressure increases in the sand filters.
Correction: Backwash the sand filter in accordance with ATCP 76.11(6)(b).
Code ATCP 76.11(6)(b)
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is below 7.0.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
Repeat
WATER TESTING FREQUENCY - POOLS
The water testing frequency for water chemistry is not in compliance with ATCP 76.18(1). Water not being tested on weekends.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
BIOHAZARD KIT UNAVAILABLE
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Non-critical
Corrected on site
SKIMMER/MAIN DRAIN RATIO INCORRECT
The skimmer to main drain flow ration is not set correctly.
Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.
Code [A] ATCP 76.11(2)(a)
-
Not serious
Non-critical
Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.