Par Terre At Emerald Row
8001 S 6TH ST, Oak Creek, WI 53154 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Oak Creek Health Department
- License / ID
- DPIN-C3EJ49
- Status
- Permitted
- Phone
- (414) 204-1300
- Official record
- Oak Creek Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 2 | 2 | 2 |
| 2024 | 3 | 19 | 6 |
| 2023 | 2 | 9 | 0 |
Inspections
-
Jun 19, 2026 Routine · No items found
No violations cited.
-
Jun 20, 2025 Follow Up · No items found
No violations cited.
-
Jun 12, 2025 Routine · 2 critical, 1 repeat
-
Serious
Critical
WATER SUPPLY PROTECTION
Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the piping going to the pool. Air gap is needed.
Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.
Code ATCP 76.19(1) - PROTECTION
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
The water to the drinking fountain has not been turned on due to a leak.
Correction: Fix leak and turn on the water supply to the fountain.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
-
Jun 25, 2024 Follow Up · 1 critical, 2 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 45ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
Repeat
LANDSCAPING MAINTENANCE
The landscaped area outside the fence that is around the pool is heaped up high which is allowing rain water to wash small stones and other debris onto the pool deck, which ultimately gets into the pool.
Correction: Maintain landscaped areas within a pool enclosure continually to prevent debris from entering the water.
Code ATCP 76.34(6)(c) -MAINTENANCE
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no functioning drinking fountain at the pool. Water has been turned off and it is waiting for repair.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Jun 19, 2024 Follow Up · 1 critical, 3 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 45ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. A template was given to the operator for writing out a plan.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
LANDSCAPING MAINTENANCE
The landscaped area outside the fence that is around the pool is heaped up high which is allowing rain water to wash small stones and other debris onto the pool deck, which ultimately gets into the pool.
Correction: Maintain landscaped areas within a pool enclosure continually to prevent debris from entering the water.
Code ATCP 76.34(6)(c) -MAINTENANCE
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no functioning drinking fountain at the pool. Water has been turned off and it is waiting for repair.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Jun 17, 2024 Routine · 4 critical, 8 non-critical
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is no conspicuously posted on an easily read chart. Operator were back washing every other day.
Correction: Post the backwash procedure on an easily read chart. Follow manufacturers recommendation, typically back wash with a rise of 9-10 psi in the filters.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 45ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. A template was given to the operator for writing out a plan.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises and the correct pool chemistry log sheet is not being used.
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The light on the side of the pool near the main drain has the frame of the light coming off the wall. A bolt was found in the pool and a bolt the same size was missing from the main drain grate.
Correction: Maintain the pool equipment. Secure the light frame to the pool wall. Replace the bolt in the main drain grate.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
LANDSCAPING MAINTENANCE
The landscaped area outside the fence that is around the pool is heaped up high which is allowing rain water to wash small stones and other debris onto the pool deck, which ultimately gets into the pool.
Correction: Maintain landscaped areas within a pool enclosure continually to prevent debris from entering the water.
Code ATCP 76.34(6)(c) -MAINTENANCE
-
Serious
Critical
Corrected on site
OPERATOR KNOWLEDGE- ELECTRICAL INTERLOCK FUNCTION
The person responsible is not able to describe how the chemical feeder electrical interlock functions.
Correction: Ensure that operator can describe how the chemical feeder electrical interlock functions. Was able to talk it through with the operator to show proper verification.
Code ATCP 76.13 (1)(c)2.b - HOW ELECTRICAL INTERLOCK FUNCTIONS
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no functioning drinking fountain at the pool. Water has been turned off and it is waiting for repair.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jul 5, 2023 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
WATER TESTING FREQUENCY - POOLS
The water testing frequency for cyanuric acid (stabilizer) is not in compliance with ATCP 76.18(1). Required to be tested weekly and no testing has been done.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT UNAVAILABLE
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Non-critical
Repeat
FIRST AID KIT UNAVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code [A] ATCP 76.27(1)
-
Not serious
Non-critical
Repeat
-
Jun 14, 2023 Routine · 6 non-critical
-
Not serious
Non-critical
TEST KIT NOT APPROVED
The reagents in the test kit used have all expired.
Correction: Replace the test kit with one from the approved list.
Code ATCP 76.17(1)
-
Not serious
Non-critical
WATER TESTING FREQUENCY - POOLS
The water testing frequency for cyanuric acid (stabilizer) is not in compliance with ATCP 76.18(1). Required to be tested weekly and no testing has been done.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
BIOHAZARD KIT UNAVAILABLE
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Non-critical
TELEPHONE NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately. Pool was closed.
Code [A] ATCP 76.26(2)
-
Not serious
Non-critical
FIRST AID KIT UNAVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code [A] ATCP 76.27(1)
-
Not serious
Non-critical
Corrected on site
DRINKING FOUNTAIN NOT FUNCTIONAL
The drinking fountain did not have running water. The drain from the drinking fountain was cracked due to freezing with water in the drain line. It was leaking water.
Correction: Water was made available.
Code [A] ATCP 76.33(1)(g)
-
Not serious
Non-critical
Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.