Fairfield Inn & Suites Whirlpool
6460 S 13TH ST, Oak Creek, WI 53154 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Oak Creek Health Department
- License / ID
- BSAW-87ES26
- Status
- Permitted
- Phone
- (414) 570-8888
- Official record
- Oak Creek Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 1 |
| 2025 | 6 | 25 | 4 |
| 2024 | 6 | 42 | 15 |
| 2023 | 2 | 13 | 2 |
Inspections
-
Jun 11, 2026 Routine · 1 critical, 1 repeat
-
Serious
Critical
Repeat
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.2 for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Pool was initially closed and chlorine was broadcasted into the pool to raise the level up to 4.0ppm of chlorine. Feeding unit was also checked to see if it was plugged.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
Corrected on site
-
Oct 14, 2025 Follow Up · No items found
No violations cited.
-
Oct 6, 2025 Follow Up · 3 non-critical, 2 repeat
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Whirlpool water is not being tested properly for chlorine. The operator is using 0.5 instead of 0.2 for the conversion factor with the number of drops of reagents used to get the chlorine levels. Chlorine levels my actually be below the required minimum.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Follow the test kit directions.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. The bobber was stuck at the bottom of the tube and not moving.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Some of the previous months were missing results.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
-
Sep 22, 2025 Follow Up · 4 non-critical, 3 repeat
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. No test results were documented for yesterday (Sunday).
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. The bobber was stuck at the bottom of the tube and not moving.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept for some of the previous months.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Some of the previous months were missing results.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
-
Sep 15, 2025 Follow Up · 1 critical, 6 non-critical, 7 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. The bobber was stuck at the bottom of the tube and not moving.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept for some of the previous months.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
TEST KIT APPROVED
The test kit on site is not an approved test kit and also the reagents used are expired.
Correction: Obtain an approved test kit such as the Taylor K-2006 or K-2106.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for some of the previous months for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Some of the previous months were missing results.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING MAINTENANCE
The electronic monitoring device has not been periodically monitored for proper functioning. The reading on the ORP shows an acceptable reading but the whirlpool water test shows chlorine levels too low. .
Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate. Calibrate and/or clean probes.
Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED
-
Serious
Critical
Repeat
WHIRLPOOL WATER TEMPERATURE
The whirlpool water temperature is 104.8°F.
Correction: Maintain the whirlpool water at greater than 90°F or 32°C, and may not exceed 104°F or 40°C.
Code ATCP 76.19(4)(c) - WHIRLPOOL WATER TEMP
-
Not serious
Non-critical
Repeat
-
Sep 12, 2025 Routine · 3 critical, 6 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. The bobber was stuck at the bottom of the tube and not moving.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept for some of the previous months.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
TEST KIT APPROVED
The test kit on site is not an approved test kit and also the reagents used are expired.
Correction: Obtain an approved test kit such as the Taylor K-2006 or K-2106.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for some of the previous months for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Some of the previous months were missing results.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING MAINTENANCE
The electronic monitoring device has not been periodically monitored for proper functioning. The reading on the ORP shows an acceptable reading but the whirlpool water test shows chlorine levels too low. .
Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate. Calibrate and/or clean probes.
Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 3.0ppm and the test level was only 1.0ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
WHIRLPOOL WATER TEMPERATURE
The whirlpool water temperature is 104.8°F.
Correction: Maintain the whirlpool water at greater than 90°F or 32°C, and may not exceed 104°F or 40°C.
Code ATCP 76.19(4)(c) - WHIRLPOOL WATER TEMP
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. Chlorine levels were at 1.0ppm with a 3.0ppm required.
Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Not serious
Non-critical
Repeat
-
Feb 19, 2025 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. The bobber inside the tube is not moving to indicate that it is not stuck.
Correction: Remove and clean out the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 999 mV and the tested chlorine levels was at 4.0ppm. Eco Lab is to come out and reset the whole system.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
-
Jul 30, 2024 Follow Up · 1 critical, 2 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% open for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates of shocking the pool not documented. Pump safety check not documented.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
Repeat
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. Reading 10.6ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
Repeat
-
Jul 29, 2024 Follow Up · 2 critical, 2 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% open for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates of shocking the pool not documented. Pump safety check not documented.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
Repeat
PH
The pH is <7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. Reading 10.6ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
Repeat
-
Jul 26, 2024 Follow Up · 2 critical, 2 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% open for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates of shocking the pool not documented. Pump safety check not documented.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
Repeat
PH
The pH is <7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. Reading 10.6ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
Repeat
-
Jul 25, 2024 Follow Up · 2 critical, 7 non-critical, 9 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% open for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 50ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 169 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TESTING BEFORE OPENING PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Pool water is not tested for pH and disinfectant or sanitizer residual before the pool is open to the public. ORP readings are taken and water maybe tested later in the day.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use and at least 4 times daily.
Code ATCP 76.18(2)(a)1.- WATER TESTED PH AN SANITIZER WIRLP, EX,
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirlpool and the whirlpool water is not tested at least twice a week for the combined chlorine level. No documentation.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirlpool water not tested at least once a week for total alkalinity. No documentation was noted.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates of shocking the pool not documented. Pump safety check not documented.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0 for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is <7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Repeat
-
Jul 24, 2024 Follow Up · 4 critical, 7 non-critical, 11 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% open for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 50ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 169 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TESTING BEFORE OPENING PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Pool water is not tested for pH and disinfectant or sanitizer residual before the pool is open to the public. ORP readings are taken and water maybe tested later in the day.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use and at least 4 times daily.
Code ATCP 76.18(2)(a)1.- WATER TESTED PH AN SANITIZER WIRLP, EX,
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirlpool and the whirlpool water is not tested at least twice a week for the combined chlorine level. No documentation.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirlpool water not tested at least once a week for total alkalinity. No documentation was noted.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates of shocking the pool not documented. Pump safety check not documented.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0 for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is <7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
FREE OF CHEMICAL, PHYSICAL, AND MICROBIAL SUBSTANCES
Pool water is not free of chemical, physical, and microbial substances known to be, or suspected of being, capable of creating toxic reactions or skin or membrane irritations. Green algae like substance is growing on the bottom of the whirlpool.
Correction: Close the pool until the water is free of chemical, physical, and microbial substances known to be, or suspected of being, capable of creating toxic reactions or skin or membrane irritations.
Code ATCP 76.16 (1) - WATER FREE OF PHYSICAL, MICROBIAL
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR POOL CLOSED
Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. Whirlpool was consistently running with a high pH (above 8) according to documentation.
Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria.
Code ATCP 76.21 (1)(c)10. - CLOSE POOL
-
Not serious
Non-critical
Repeat
-
Jul 23, 2024 Routine · 4 critical, 7 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% open for each valve.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 169 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TESTING BEFORE OPENING PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Pool water is not tested for pH and disinfectant or sanitizer residual before the pool is open to the public. ORP readings are taken and water maybe tested later in the day.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use and at least 4 times daily.
Code ATCP 76.18(2)(a)1.- WATER TESTED PH AN SANITIZER WIRLP, EX,
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirlpool and the whirlpool water is not tested at least twice a week for the combined chlorine level. No documentation.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirlpool water not tested at least once a week for total alkalinity. No documentation was noted.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates of shocking the pool not documented. Pump safety check not documented.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0 for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is <7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
FREE OF CHEMICAL, PHYSICAL, AND MICROBIAL SUBSTANCES
Pool water is not free of chemical, physical, and microbial substances known to be, or suspected of being, capable of creating toxic reactions or skin or membrane irritations. Green algae like substance is growing on the bottom of the whirlpool.
Correction: Close the pool until the water is free of chemical, physical, and microbial substances known to be, or suspected of being, capable of creating toxic reactions or skin or membrane irritations.
Code ATCP 76.16 (1) - WATER FREE OF PHYSICAL, MICROBIAL
-
Serious
Critical
RESPONSIBLE SUPERVISOR POOL CLOSED
Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. Whirlpool was consistently running with a high pH (above 8) according to documentation.
Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria.
Code ATCP 76.21 (1)(c)10. - CLOSE POOL
-
Not serious
Non-critical
Repeat
-
Oct 26, 2023 Follow Up · 1 critical, 1 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
No combined chlorine plan was available or deleveloped.
Correction: A template for developing a combined chlorine plan was given to the operator.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
Repeat
OPERATOR KNOWLEDGE SAFETY DURING MONTHLY TESTING
The person responsible is not able to describe what safety measures that must be employed during monthly testing. Has not been testing monthly or no documentation of any monthly testing.
Correction: Ensure that operator can describe what safety measures that must be employed during monthly testing.
Code ATCP 76.13 (1)(c)2.e -MONTHLY TESTING SAFETY
-
Not serious
Non-critical
Repeat
-
Oct 19, 2023 Routine · 1 critical, 10 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 100% skimmer and 0% from the main drain.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition. The bobber inside the meter was not moving, indicating that it is stuck.
Correction: Clean out the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is no conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
RAPID RATE SAND FILTER BACKWASHING
Rapid rate sand filter not backwashed as recommended by manufacturer. Operator stated they back wash once per week and are not using the pressure rise in the sand filter.
Correction: Backwash in accordance with manufacturer.
Code ATCP 76.11(6)(b) 1. - RAPID RATE SAND FILTER BACKWASH
-
Not serious
Non-critical
LABEL, NAME OF PRODUCT
Container label does not list name of product. Container of acid does not have a label on to indicate what it is.
Correction: Provide the name of the product on the label.
Code ATCP 76.12 (1)(a) 1. - PRODUCT NAME
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
No combined chlorine plan was available or deleveloped.
Correction: A template for developing a combined chlorine plan was given to the operator.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. The dates observed on the bottles of reagents were mostly all expired. Operator did not know if they were being refilled from a bigger bottle. Reagents are stored in the hot pump room.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. No documentation was observed.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing. No free chlorine test results, no combined chlorine test results, backwashing, shocking of pool results, interlock testing, and adding of pool chemicals were not documented.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Serious
Critical
OPERATOR KNOWLEDGE SAFETY DURING MONTHLY TESTING
The person responsible is not able to describe what safety measures that must be employed during monthly testing. Has not been testing monthly or no documentation of any monthly testing.
Correction: Ensure that operator can describe what safety measures that must be employed during monthly testing.
Code ATCP 76.13 (1)(c)2.e -MONTHLY TESTING SAFETY
-
Not serious
Non-critical
Corrected on site
Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.