RecordWell Data

Fairfield Inn & Suites Pool

6460 S 13TH ST, Oak Creek, WI 53154 · Milwaukee County

61cited violations
17serious tier
15inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Oak Creek Health Department
License / ID
BSAW-87ERZV
Status
Permitted
Phone
(414) 570-8888
Official record
Oak Creek Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
20256216
20246258
20232153

Inspections

  1. Jun 11, 2026 Routine · No items found

    No violations cited.

  2. Oct 14, 2025 Follow Up · No items found

    No violations cited.

  3. Oct 6, 2025 Follow Up · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not being accurately tested and recorded on the log sheet. Results on the log sheet were with odd numbers like 4.5, 5.5. It appears the proper conversion per the number of drops used is not being used. (0.5 instead of 0.2)???

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Follow directions as written in the test kit to get accurate results.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Serious Critical Repeat

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, and another approved device does not exist. An air gap of about an inch is required between the water supply inlet pipe and the pipe going to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

  4. Sep 22, 2025 Re-inspection · 1 critical, 2 non-critical, 2 repeat
    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. No test results were documented for yesterday (Sunday). No testing was done yet today (noon) but the pool appeared to be closed with a sign posted at the pool entrance door.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept. Various months showed no documentation of this safey check.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Serious Critical Repeat

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, and another approved device does not exist. An air gap of about an inch is required between the water supply inlet pipe and the pipe going to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

  5. Sep 15, 2025 Follow Up · 1 critical, 5 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept. Various months showed no documentation of this safey check.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The test kit used is not an approved test kit and the reagents are expired.

      Correction: Replace test kit with an approved test kit. Taylor K-2006 or Taylor K-2106.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Combined chlorine has been tested occasionally, with some months no results documented.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. No results were documented some of the previous months.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING MAINTENANCE

      The electronic monitoring device has not been periodically adjusted to function properly. The chlorine levels tested in the pool water have been consistently below the minimun concentration required, even though the ORP controller is reading proper numbers indicating acceptable chlorine levels.

      Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate. May need to calibrate or clean probes.

      Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED

    • Serious Critical Repeat

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, and another approved device does not exist. An air gap of about an inch is required between the water supply inlet pipe and the pipe going to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

  6. Sep 12, 2025 Routine · 3 critical, 5 non-critical
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept. Various months showed no documentation of this safey check.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      TEST KIT APPROVED

      The test kit used is not an approved test kit and the reagents are expired.

      Correction: Replace test kit with an approved test kit. Taylor K-2006 or Taylor K-2106.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Combined chlorine has been tested occasionally, with some months no results documented.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. No results were documented some of the previous months.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING MAINTENANCE

      The electronic monitoring device has not been periodically adjusted to function properly. The chlorine levels tested in the pool water have been consistently below the minimun concentration required, even though the ORP controller is reading proper numbers indicating acceptable chlorine levels.

      Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate. May need to calibrate or clean probes.

      Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.0ppm and the level tested was only 0.4ppm for chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Minimum of 1.0ppm and maximum of 10.0ppm.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, and another approved device does not exist. An air gap of about an inch is required between the water supply inlet pipe and the pipe going to the pool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. The chlorine level was 0.4ppm and the pool was not closed. Past records also indicated that some days the pool testing indicated no chlorine in the water but no action was taken to correct this.

      Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14 (1.0-10.0ppm), or pH values that are less than 6.8 or equal to or greater than 8.0.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

  7. Jan 17, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      It appears the flow meter bobber is stuck as it is not bobbing up and down to indicate it is working.

      Correction: Adjust or repair the bobber.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      Results for pool water chemistry testing were not accurately reported on the log sheet. Some results for pH were not consistent with results that would be gotten from using the Taylor test kit. These results recorded were taken from the ORP readings and not from testing the pool water with the Taylor test kit. Alkalinity is required to be tested once per week and I observed once per month. No documentation was noted for backwashing, shocking the pool, and if chlorine levels were low on what was done.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

  8. Jul 30, 2024 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates for shocking the pool. Pump safety checks not documented.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

  9. Jul 29, 2024 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates for shocking the pool. Pump safety checks not documented.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical Repeat

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck..

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

  10. Jul 26, 2024 Follow Up · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates for shocking the pool. Pump safety checks not documented.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck..

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

  11. Jul 25, 2024 Re-inspection · 1 critical, 4 non-critical, 5 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 0. The test water turned red immediately when adding the green reagent.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. No results were documented on the log sheet for the past number of months.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. No results were documented on the pool log sheet for the past number of months.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates for shocking the pool. Pump safety checks not documented.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical Repeat

      PH

      The pH is <7.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  12. Jul 24, 2024 Follow Up · 2 critical, 5 non-critical, 7 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 0. The test water turned red immediately when adding the green reagent.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Operator stated she uses the ORP reading in the morning and test later in the day.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. No results were documented on the log sheet for the past number of months.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. No results were documented on the pool log sheet for the past number of months.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates for shocking the pool. Pump safety checks not documented.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical Repeat

      PH

      The pH is <7.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Repeat

      RESPONSIBLE SUPERVISOR POOL CLOSED

      Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. Pool water chemistry was documented consistently above a pH of 8.0 and low chlorine.

      Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria.

      Code ATCP 76.21 (1)(c)10. - CLOSE POOL

  13. Jul 23, 2024 Routine · 3 critical, 5 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 0. The test water turned red immediately when adding the green reagent.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Operator stated she uses the ORP reading in the morning and test later in the day.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. No results were documented on the log sheet for the past number of months.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. No results were documented on the pool log sheet for the past number of months.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. Dates for shocking the pool. Pump safety checks not documented.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.2ppm of chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Minimum is 1.0ppm.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is <7.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      RESPONSIBLE SUPERVISOR POOL CLOSED

      Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. Pool water chemistry was documented consistently above a pH of 8.0 and low chlorine.

      Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria.

      Code ATCP 76.21 (1)(c)10. - CLOSE POOL

  14. Oct 26, 2023 Follow Up · 1 critical, 2 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 40ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      No combined chlorine plan is available.

      Correction: Develop a combined chlorine plan with the template provided.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical Repeat

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed. No documentation of testing is not performed as no testing is done monthly

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

  15. Oct 19, 2023 Routine · 2 critical, 10 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain with both main drain and skimmer valves open at 100%.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer. Adjusted to skimmer open 80% and drain valve open 20%.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      RAPID RATE SAND FILTER BACKWASHING

      Rapid rate sand filter not backwashed as recommended by manufacturer. Operator stated they backwash once per week instead of following the recommended rise of 9-11 psi of pressure in the filters.

      Correction: Backwash in accordance with manufacturer.

      Code ATCP 76.11(6)(b) 1. - RAPID RATE SAND FILTER BACKWASH

    • Not serious Non-critical

      LABEL, NAME OF PRODUCT

      Container label does not list name of product. Acid container does not have a label to indicate what it is.

      Correction: Provide the name of the product on the label.

      Code ATCP 76.12 (1)(a) 1. - PRODUCT NAME

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      No combined chlorine plan is available.

      Correction: Develop a combined chlorine plan with the template provided.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Corrected on site

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 492 mV due to no chlorine powder added to the erosion feeder.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Most of the reagents were expired according to the dates on the bottles. Operator was not sure if these bottles were refilled from a bigger bottle.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine or it is not documented if it is tested.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. Combined chlorine, free chlorine, interlock testing, backwashing, pool shocking, or adding any other chemicals.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed. No documentation of testing is not performed as no testing is done monthly

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is .2ppm for chlorine in the pool. Pool was closed and 2 hours later was retested and was at 3.4ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

Source: Oak Creek Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.