Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Oak Creek Health Department
License / ID
HSAT-7QXJ3U
Status
Permitted
Phone
(414) 570-1111
Official record
Oak Creek Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026151
2025264
2024293
2023120

Inspections

  1. May 19, 2026 Routine · 1 critical, 4 non-critical, 1 repeat
    • Not serious Non-critical

      COMBINED CHLORINE PLAN ACTION LEVEL

      The combined chlorine plan does not include the combined chlorine action level.

      Correction: Includes the combined chlorine action level in the combined chlorine plan.

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical

      ELECTRONIC MONITORING FREQUENCY OF TESTING

      The whirlpool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual. Tito is off Sunday's and Monday's and no one else has been testing the pool water.

      Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.

      Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items, including gauze pads, adhesive bandages, gauze roller bandage, adhesive tape, elastic bandages, emergency blankets.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Serious Critical Repeat Corrected on site

      TELEPHONE ACCESSIBLE

      Emergency phone was not working at the time of inspection.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  2. Sep 4, 2025 Follow Up · No items found

    No violations cited.

  3. Aug 27, 2025 Routine · 4 critical, 2 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain was set at 100% from each.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 30ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      VARIANCE, APPROVED, FOLLOWED

      Conditions for a variance have not been followed with a routine call with the emergency phone to verify it is working properly.

      Correction: Comply with the terms of the variance.

      Code ATCP 76.02(2)(b)1 - VARIANCE, APPROVED, FOLLOWED

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.4 for chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Shock was added to raise chlorine levels to 9.0, initially.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Corrected on site

      TELEPHONE ACCESSIBLE

      A telephone was not working initially due to the volume turned way down.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services. Volume was turned to normal.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      CO ALARM-POOL AREA

      There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.

      Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA

  4. Dec 17, 2024 Routine · 1 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. Some of the deck tiles are missing, cracked, damaged along with some of the grouting and caulking.

      Correction: Maintain pool deck area in good repair. Replace damaged tiles or missing tiles along with grouting and caulking.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      TELEPHONE-LOCATION

      The telephone or other approved communication technology is not within 25 feet of pool area. A call from the phone in the pool area goes to the hotel front desk, who then calls 911.

      Correction: Provide a telephone or other telecommunication technology device that is within 25 feet of pool area. Obtain a variance approval from Oak Creek and DATCP.

      Code ATCP 76.26(2)(c) - TELEPHONE, LOCATION

  5. Mar 6, 2024 Routine · 2 critical, 4 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is 100% skimmer and 80% main drain.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      CERTIFIED OPERATOR PROVIDED WITHIN 90 DAYS OF WHEN REQUIRED

      A pool that was required to have a certified operator within 90 days does not yet have a certified operator.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)3 - CERTFIED OPERATOR, 90 DAYS OF NEED FOR O

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. PIC did not know when the drain covers and equalizer covers were replaced. Equalizer covers are expired according to information from past inspections.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Serious Critical Corrected on site

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm. Was at over 12ppm. Was high due to shock added this morning. Pool was not closed.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A. Chemical was added to lower the chlorine level to 6.8.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical Corrected on site

      CLOSING CRITERIA-POOL UNDERGOING MAINTENANCE OR REPAIR

      The Responsible Supervisor or operator has not closed the pool when the pool is undergoing maintenance or repair. Whirlpool was shocked this morning and the chlorine level was above 10ppm. Guest were at tables near the whirlpool but did not go into the whirlpool.

      Correction: Close the pool when the pool is undergoing maintenance or repair.

      Code ATCP 76.30 (1)(h) - POOL UNDERGOING MAINTENANCE

  6. Jul 27, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE

      The combined chlorine is 1.2ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer. Maximum allowed is .8ppm.

      Code ATCP 76.14(4)(e)

    • Not serious Non-critical Corrected on site

      FIRST AID KIT UNAVAILABLE

      A first aid kit is not available in the pool area. Previously approved signage placed on the empty first aid box was missing. It sent patrons to the front desk.

      Correction: Provide a first aid kit in the pool area.

      Code [A] ATCP 76.27(1)