Eg & Jg
6447 CHARLES ST, Racine, WI 53402 · Racine County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Central Racine County Health Department
- License / ID
- CDYA-DUJQAN
- Status
- Permitted
- Official record
- Central Racine County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 4 | 0 |
Inspections
-
Jun 4, 2026 Pre-inspection Follow Up · No items found
No violations cited.
-
Jun 2, 2026 Pre-inspection · 4 non-critical
-
Not serious
Priority Foundation
Carbon monoxide alarm installation - FBA outside IKU
A carbon monoxide alarm is not provided outside of each separate sleeping area within the house. Only a smoke alarm is provided on the second floor by the bedrooms.
Correction: Provide carbon monoxide alarm outside of the sleeping areas on the second floor of the house. The alarm must located so it is within 21 feet of each sleeping room door.
Code ATCP 72.18(12)(c)
-
Not serious
Priority Foundation
Guard spacing <= 6"
The space between guards on the split stairway railings between the 1st and 2nd floors is at 8 inches.
Correction: Modify the space between guards on the split stairway railings between the 1st and 2nd floor to be equal to or less than 6 inches.
Code ATCP 72.18(2)(b)3.
-
Not serious
Priority Foundation
Stairs - area formed by riser, tread, bottom guard <= 8"
The triangular area formed by the tread, riser and bottom guard on the split stair case between the 1st and 2nd floor is 9 inches in width.
Correction: Modify the triangular area formed by the tread, riser and bottom guard on the split stair case between the 1st and 2nd floor to be equal to or less than 8 inches in width.
Code ATCP 72.18(2)(b)5.
-
Not serious
Priority Foundation
Guard height >= 36" - elevated surfaces
The guard rail height is less than 36 inches on second floor in various areas as measured vertically above the adjacent walking surface. 33.5 inches measured.
Correction: Modify the guard rail height to be equal to or greater than 36 inches on all second floor rails as measured vertically above the adjacent walking surface.
Code ATCP 72.18(2)(b)6.a.
-
Not serious
Priority Foundation
Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.