RecordWell Data

Eg & Jg

6447 CHARLES ST, Racine, WI 53402 · Racine County

4cited violations
0serious tier
2inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Central Racine County Health Department
License / ID
CDYA-DUJQAN
Status
Permitted
Official record
Central Racine County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026240

Inspections

  1. Jun 4, 2026 Pre-inspection Follow Up · No items found

    No violations cited.

  2. Jun 2, 2026 Pre-inspection · 4 non-critical
    • Not serious Priority Foundation

      Carbon monoxide alarm installation - FBA outside IKU

      A carbon monoxide alarm is not provided outside of each separate sleeping area within the house. Only a smoke alarm is provided on the second floor by the bedrooms.

      Correction: Provide carbon monoxide alarm outside of the sleeping areas on the second floor of the house. The alarm must located so it is within 21 feet of each sleeping room door.

      Code ATCP 72.18(12)(c)

    • Not serious Priority Foundation

      Guard spacing <= 6"

      The space between guards on the split stairway railings between the 1st and 2nd floors is at 8 inches.

      Correction: Modify the space between guards on the split stairway railings between the 1st and 2nd floor to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation

      Stairs - area formed by riser, tread, bottom guard <= 8"

      The triangular area formed by the tread, riser and bottom guard on the split stair case between the 1st and 2nd floor is 9 inches in width.

      Correction: Modify the triangular area formed by the tread, riser and bottom guard on the split stair case between the 1st and 2nd floor to be equal to or less than 8 inches in width.

      Code ATCP 72.18(2)(b)5.

    • Not serious Priority Foundation

      Guard height >= 36" - elevated surfaces

      The guard rail height is less than 36 inches on second floor in various areas as measured vertically above the adjacent walking surface. 33.5 inches measured.

      Correction: Modify the guard rail height to be equal to or greater than 36 inches on all second floor rails as measured vertically above the adjacent walking surface.

      Code ATCP 72.18(2)(b)6.a.

Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.