Inspections

  1. Jul 2, 2026 Follow Up · 3 non-critical, 2 repeat
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 203. SI at +0.67.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items. Missing- adhesive bandages, adhexive tape, eye wash, elastic bandage, gloves, CPR mask, Instant cold packs, 2 blankets.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical Repeat

      BIOHAZARD KIT ITEMS

      The biohazard kit is present but missing items. Missing- sanitizing hand wipes, sanitizing surface wipes, gloves, paper towel, twist tie, biohazard sorbent.

      Correction: Replace the missing items in the biohazard kit.

      Code ATCP 76.27(2)(b) - BIOHAZARD KIT ITEMS

  2. Jun 30, 2026 Routine · 2 critical, 4 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The current turnover rate is >7.5 hrs.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate to 6 hrs or less.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 249.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items. Missing- adhesive bandages, adhexive tape, eye wash, elastic bandage, gloves, CPR mask, Instant cold packs, 2 blankets.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      BIOHAZARD KIT ITEMS

      The biohazard kit is present but missing items. Missing- sanitizing hand wipes, sanitizing surface wipes, gloves, paper towel, twist tie, biohazard sorbent.

      Correction: Replace the missing items in the biohazard kit.

      Code ATCP 76.27(2)(b) - BIOHAZARD KIT ITEMS

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is .49 for Bromine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is 8.21.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  3. Aug 14, 2025 Follow Up · No items found

    No violations cited.

  4. Aug 11, 2025 Follow Up · 1 critical, 1 repeat
    • Serious Critical Repeat

      PH

      The pH is 6.8.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  5. Aug 6, 2025 Follow Up · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 182.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical Repeat

      MAXIMUM BROMINE

      The maximum total bromine exceeds 10 ppm. Bromine is at 32.22 during inspection. Pool is closed.

      Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.

      Code ATCP 76.14(5)(g) -MAXIMUM BROMINE

  6. Jul 31, 2025 Follow Up · 1 critical, 1 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 228.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.83 for Bromine. Pool is closed.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  7. Feb 6, 2025 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical Repeat

      FIRST AID KIT-ELASTIC BANDAGE

      The first aid kit is missing an elastic bandage.

      Correction: Provide an elastic bandage for the first aid kit.

      Code ATCP 76.27(1)(b)6. - ELASTIC BANDAGE

  8. Feb 5, 2025 Routine · 2 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      FIRST AID KIT-ELASTIC BANDAGE

      The first aid kit is missing an elastic bandage.

      Correction: Provide an elastic bandage for the first aid kit.

      Code ATCP 76.27(1)(b)6. - ELASTIC BANDAGE

    • Serious Critical

      PH

      The pH is 8.1.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better. Pool is to remain closed until the pH is lowered to within range.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      MAXIMUM BROMINE

      The maximum total bromine exceeds 10 ppm. Bromine level was 11.60ppm.

      Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.

      Code ATCP 76.14(5)(g) -MAXIMUM BROMINE

  9. Nov 22, 2023 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming.

      Correction: The strainer baskets are tapered and restricting the floating wier to bob up and down. Either change the strainer baskets to a non-tapered to allow the floating wier to bob or change wier to fit the strainer basket or a wier door.

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      REAGENTS REPLACED

      Some of the test kit reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Serious Critical

      CO ALARM-POOL AREA

      The CO alarm provided in the indoor pool area is expired as of 11/2021.

      Correction: Replace the CO alarm in the pool area and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA

  10. Jul 25, 2023 Pre-inspection · 1 non-critical
    • Not serious Non-critical

      MSDS AVAILABILITY

      Material safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide material safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)