Image Management Family Branch YMCA
8501 CAMPUS DR, Mt Pleasant, WI 53406 · Racine County
Establishment
- Type
- Pool / recreational water (Pool - Complex with Features)
- Inspected by
- Central Racine County Health Department
- License / ID
- KHES-8XGN3W
- Status
- Permitted
- Official record
- Central Racine County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 2 |
| 2025 | 1 | 2 | 0 |
| 2024 | 1 | 6 | 4 |
| 2023 | 2 | 8 | 0 |
Inspections
-
Apr 7, 2026 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Gutter grate cracked in the SW corner of the pool
Correction: Repair or replace gutter grate as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
SLIDES, RULES NOT PROVIDED
Rules sign for a pool slide or waterslide is deteriorated and some words are no longer legible.
Correction: Replace the rules sign for the pool slide or waterslide.
Code ATCP 76.29(2)(a) - RULES FOR SLIDES
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. There is a severe leak from the pump.
Correction: Repair the leak coming from the pump and maintain the pool equipment
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
NO PATRONS IN POOL, MAINTENANCE
Patrons were in the pool during pool maintenance operations.
Correction: Ensure that no patrons are in the pool while maintenance is occurring.
Code ATCP 76.24(1) - NO PATRONS IN POOL DURING MAINTENANCE
-
Serious
Critical
RING BOUY
A ring buoy not provided at the whirlpool area life guard chair.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Not serious
Non-critical
-
Apr 28, 2025 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Part of the gutter is cracked and missing near the lazy river and water slide..
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
-
Apr 17, 2024 Routine · 4 critical, 2 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 56.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
Corrected on site
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. The free chlorine was 11.42. The free chlorine was lowered to 7.17 during inspection.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Serious
Critical
WATER ATTRACTIONS-WATERSLIDES 6 FEET OR HIGHER, INSPECTION
A waterslide 6 feet or higher has not been inspected by an engineer or the signed report from the engineer is missing. The last inspection was conducted on 7/26/2017
Correction: Have an engineer evaluate the waterslide for the structural stability and integrity of the slide and platform and maintain the signed report from the engineer.
Code ATCP 76.37(2)(c) - WATERSLIDE INSPECTED BY ENGINEER
-
Not serious
Non-critical
-
Jun 9, 2023 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE
The combined chlorine is 1.06.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Non-critical
Repeat
MAXIMUM PATRON LOAD NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).
Code [A] ATCP 76.29(1)(d)
-
Not serious
Non-critical
Repeat
MONTHLY OPERATION REPORTS NOT SUBMITTED
Monthly operation reports are not being kept in accordance with ATCP 76.32(1).
Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).
Code [A] ATCP 76.32(1)
-
Not serious
Non-critical
Repeat
-
May 19, 2023 Routine · 5 non-critical, 2 repeat
-
Not serious
Non-critical
Corrected on site
pH OUT OF BALANCE
The pH is 8.1. The pH was adjusted to 7.8 during inspection..
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
COMBINED CHLORINE
The combined chlorine is 1.06.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Non-critical
Repeat
TELEPHONE NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code [A] ATCP 76.26(2)
-
Not serious
Non-critical
MAXIMUM PATRON LOAD NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).
Code [A] ATCP 76.29(1)(d)
-
Not serious
Non-critical
Repeat
MONTHLY OPERATION REPORTS NOT SUBMITTED
Monthly operation reports are not being kept in accordance with ATCP 76.32(1).
Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).
Code [A] ATCP 76.32(1)
-
Not serious
Non-critical
Corrected on site
Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.