Clarion Pointe By Choice Hotels
1154 PRAIRIE DR, Racine, WI 53406 · Racine County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Central Racine County Health Department
- License / ID
- WKRR-AMPRFN
- Status
- Permitted
- Phone
- (262) 886-6055
- Official record
- Central Racine County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 3 | 8 | 2 |
| 2024 | 2 | 7 | 4 |
Inspections
-
Dec 30, 2025 Routine · 6 non-critical
-
Not serious
Non-critical
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is backward. Skimmer valve is restricted and main drain valve is wide open.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
The main drain cover is missing 2 screws.
Correction: Pool must be closed immediately and replace missing screws. Text photo of the screws in place once repaired.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not operational.
Correction: Repair or replace the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for a pool shock, defoaming solution and jet cleaner solution.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Corrected on site
WATER LEVEL-SKIMMERS MAINTAINED
Water level is too high and covering the skimmer.
Correction: Maintain the water level in the pool so that the skimmer weir is half submerged.
Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED
-
Not serious
Non-critical
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone.
Correction: Sign was created and hung during inspection.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
-
Feb 27, 2025 Routine · 2 critical, 1 repeat
-
Serious
Critical
PH
The pH is 8.6. The pool must remain closed until the pH is between 7.2-7.8
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm. The bromine is 33.13 ppm. The pool is closed until the bromine is between 4-10 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Serious
Critical
-
Feb 27, 2025 Follow Up · No items found
No violations cited.
-
Mar 5, 2024 Routine · 3 critical, 2 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmer is not maintained clean.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
FIRST AID KIT-EYE WASH SOLUTION
The first aid kit is missing eye wash solution.
Correction: Provide eye wash solution for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Serious
Critical
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm. The bromine total is 22.02 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Serious
Critical
Corrected on site
GATES AND DOORS-SELF-CLOSING
The door to the pool was propped open by a door stop at time of inspection. The door is self-closing and able to be locked.
Correction: Keep the door closed at all times.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
-
Mar 5, 2024 Follow Up · 1 critical, 1 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
FIRST AID KIT-EYE WASH SOLUTION
The first aid kit is missing eye wash solution.
Correction: Provide eye wash solution for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Serious
Critical
Repeat
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
Repeat